uhd/mpm/python/usrp_mpm/simulator/chdr_stream.py

258 lines
10 KiB
Python
Raw Normal View History

#
# Copyright 2020 Ettus Research, a National Instruments Brand
#
# SPDX-License-Identifier: GPL-3.0-or-later
#
"""
This module contains the streaming backend for the simulator. It
handles managing threads, as well as interfacing with sample sources
and sinks.
"""
import time
from threading import Thread
import queue
import socket
from uhd.chdr import PacketType, StrcOpCode, StrcPayload, StrsPayload, StrsStatus, ChdrHeader, ChdrPacket
class XferCount:
"""This class keeps track of flow control transfer status which are
used to populate Strc and Strs packets
"""
def __init__(self):
self.num_bytes = 0
self.num_packets = 0
@classmethod
def from_strc(cls, payload):
"""Construct an XferCount from a Strc Payload"""
xfer = cls()
xfer.num_packets = payload.num_pkts
xfer.num_bytes = payload.num_bytes
return xfer
@classmethod
def from_strs(cls, payload):
xfer = cls()
xfer.num_packets = payload.xfer_count_pkts
xfer.num_bytes = payload.xfer_count_bytes
return xfer
def has_exceeded(self, limit):
"""returns true if this XferCount >= the limit
in either packets or bytes
"""
return self.num_packets >= limit.num_packets or self.num_bytes >= limit.num_bytes
def count_packet(self, len):
"""Account for a len bytes sized packet transfer"""
self.num_bytes += len
self.num_packets += 1
def clear(self):
"""Reset the counts to zero"""
self.num_bytes = 0
self.num_packets = 0
def __str__(self):
return "XferCount{{num_bytes:{}, num_packets:{}}}".format(self.num_bytes, self.num_packets)
class ChdrInputStream:
"""This class encapsulates an Rx Thread. This thread blocks on a
queue which receives STRC and DATA ChdrPackets. It places the data
packets into the sample_sink and responds to the STRC packets using
the send_wrapper
"""
CAPACITY_BYTES = int(5e3) # 5 KB
QUEUE_CAP = 3
def __init__(self, log, chdr_w, sample_sink, send_wrapper, our_epid):
self.log = log
self.chdr_w = chdr_w
self.sample_sink = sample_sink
self.send_wrapper = send_wrapper
self.xfer = XferCount()
self.accum = XferCount()
self.fc_freq = None
self.command_target = None
self.command_addr = None
self.command_epid = None
self.our_epid = our_epid
self.rx_queue = queue.Queue(ChdrInputStream.QUEUE_CAP)
self.stop = False
self.thread = Thread(target=self._rx_worker, daemon=True)
self.thread.start()
def _rx_worker(self):
self.log.info("Stream RX Worker Starting")
while True:
packet, recv_len, addr = self.rx_queue.get()
# This break is here because when ChdrInputStream.stop() is called,
# a tuple of 3 None values is pushed into the queue to unblock the worker.
if self.stop:
break
header = packet.get_header()
self.xfer.count_packet(recv_len)
self.accum.count_packet(recv_len)
pkt_type = header.pkt_type
if pkt_type in (PacketType.DATA_WITH_TS, PacketType.DATA_NO_TS):
self.sample_sink.accept_packet(packet)
elif pkt_type == PacketType.STRC:
req_payload = packet.get_payload_strc()
# Ping doesn't change anything, just requests a stream status packet
if req_payload.op_code == StrcOpCode.INIT:
self.xfer.clear()
self.fc_freq = XferCount.from_strc(req_payload)
self.command_addr = addr
self.command_epid = req_payload.src_epid
elif req_payload.op_code == StrcOpCode.RESYNC:
self.xfer = XferCount.from_strc(req_payload)
resp_packet = self._generate_strs_packet(req_payload.src_epid, self.our_epid)
self.send_wrapper.send_packet(resp_packet, addr)
else:
raise RuntimeError("RX Worker received unsupported packet: {}".format(pkt_type))
# Check if a fc status packet is due
if self.fc_freq is not None and self.accum.has_exceeded(self.fc_freq):
self.accum.clear()
self.log.trace("Flow Control Due, sending STRS")
self.command_target = None
resp_packet = self._generate_strs_packet(self.command_epid, self.our_epid)
self.log.trace("Sending Flow Control: {}".format(resp_packet.to_string_with_payload()))
self.send_wrapper.send_packet(resp_packet, self.command_addr)
self.sample_sink.close()
self.log.info("Stream RX Worker Done")
def finish(self):
"""Unblocks the worker and stops the thread.
The worker will close its sample_sink
"""
self.stop = True
self.rx_queue.put((None, None, None))
def _generate_strs_packet(self, dst_epid, src_epid):
"""Create an strs packet from the information in self.xfer"""
resp_header = ChdrHeader()
resp_header.dst_epid = dst_epid
resp_payload = StrsPayload()
resp_payload.src_epid = src_epid
resp_payload.status = StrsStatus.OKAY
resp_payload.capacity_bytes = ChdrInputStream.CAPACITY_BYTES
resp_payload.capacity_pkts = 0xFFFFFF
resp_payload.xfer_count_bytes = self.xfer.num_bytes
resp_payload.xfer_count_pkts = self.xfer.num_packets
resp_packet = ChdrPacket(self.chdr_w, resp_header, resp_payload)
return resp_packet
def queue_packet(self, packet, recv_len, addr):
"""Queue a packet to be processed by the ChdrInputStream"""
self.rx_queue.put((packet, recv_len, addr))
class ChdrOutputStream:
"""This class encapsulates a Tx Thread. It takes data from its
sample_source and then sends it in a data packet using its
send_wrapper.
The tx stream is configured using the stream_spec object, which
sets parameters such as sample rate and destination
"""
def __init__(self, log, chdr_w, sample_source, stream_spec, send_wrapper):
self.log = log
self.chdr_w = chdr_w
self.sample_source = sample_source
self.stream_spec = stream_spec
self.send_wrapper = send_wrapper
self.xfer = XferCount()
self.recv = XferCount()
self.stop = False
self.strs_queue = queue.Queue(100)
self.strc_seq_num = 0
self.data_seq_num = 0
self.thread = Thread(target=self._tx_worker, daemon=True)
self.thread.start()
def _tx_worker(self):
self.log.info("Stream TX Worker Starting with {} packets/sec"
.format(1/self.stream_spec.seconds_per_packet()))
self.log.info("Downstream Buffer Capacity: {} packets or {} bytes"
.format(self.stream_spec.capacity_packets, self.stream_spec.capacity_bytes))
header = ChdrHeader()
start_time = time.time()
next_send = start_time
header.dst_epid = self.stream_spec.dst_epid
header.pkt_type = PacketType.DATA_NO_TS
is_continuous = self.stream_spec.is_continuous
num_samps_left = None
if not is_continuous:
# TODO: Put sample format/width in the stream spec
num_samps_left = self.stream_spec.total_samples * 4 # SC16 is 4 bytes per sample
timestamp = self.stream_spec.init_timestamp \
if self.stream_spec.is_timed else None
while is_continuous or num_samps_left > 0:
if self.stop:
self.log.info("Stream Worker Stopped")
break
header.seq_num = self.data_seq_num
# When seq_num gets to 65535 (Max Unsigned 16 bit integer)
# It wraps back around to 0
self.data_seq_num = int(self.data_seq_num + 1) & 0xFFFF
packet = ChdrPacket(self.chdr_w, header, bytes(0), timestamp)
packet_samples = self.stream_spec.packet_samples
if num_samps_left is not None:
packet_samples = min(packet_samples, num_samps_left)
num_samps_left -= packet_samples
packet = self.sample_source.fill_packet(packet, packet_samples)
if packet is None:
break
send_data = bytes(packet.serialize()) # Serialize before waiting
delay = next_send - time.time()
if delay > 0:
time.sleep(delay)
next_send = next_send + self.stream_spec.seconds_per_packet()
timestamp = None
# Check Flow Control to assert there is space downstream
while not self._can_fit_packet(len(send_data)):
strs_update = self.strs_queue.get()
strs_payload = strs_update.get_payload_strs()
self._update_recv(strs_payload)
self.send_wrapper.send_data(send_data, self.stream_spec.addr)
self.xfer.count_packet(len(send_data))
self.log.info("Stream Worker Done")
finish_time = time.time()
self.log.info("Actual Packet Rate was {} packets/sec"
.format(self.xfer.num_packets/(finish_time - start_time)))
self.sample_source.close()
def finish(self):
"""Stops the ChdrOutputStream"""
self.stop = True
def queue_packet(self, packet):
""" Place an incoming STRS packet in the Queue """
self.strs_queue.put_nowait(packet)
def _can_fit_packet(self, length):
""" Can the downstream buffer fit a packet of length right now """
packets_in_transit = self.xfer.num_packets - self.recv.num_packets
space_packets = self.stream_spec.capacity_packets - packets_in_transit
bytes_in_transit = self.xfer.num_bytes - self.recv.num_bytes
space_bytes = self.stream_spec.capacity_bytes - bytes_in_transit
return space_packets > 0 and space_bytes >= length
def _update_recv(self, strs_payload):
""" Update the Xfer counts for downstream receive using
an incoming strs payload
"""
assert strs_payload.status == StrsStatus.OKAY, \
"Flow Control Error: STRS Status is {}".format(strs_payload.status)
self.recv.num_packets = strs_payload.xfer_count_pkts
self.recv.num_bytes = strs_payload.xfer_count_bytes