bunnie a4c97a410c handle time panics more gracefully; work around RTC HW issues
- don't hard panic if the time seems wrong; just clear
the PDDB entries, and move on. This at least allows the
user to intervene to fix the time, intsead of insta-crashing
when anything seems wrong and depriving users an opportunity
to fix anything

- fix HW derpiness by introducing some dummy reads during
the resetting of the hardware process.

One thing I wanted to do was to have the RTC always powered
off of the battery. This is not a default mode but it's an
option. In theory, this is a more efficient because anyways,
VDD comes from VBAT, right? However, the RTC hardware gets
a little side-eye when VBAT is higher than VDD most of the
time and reports a strange error code. The power savings
is miniscule -- some tens of nanowatts -- so I'm not going
to fight with the RTC hardware quirks anymore.