Here's an arcane bug for you: When powering down, the Spartan 7 3.3V I/O drivers will output a roughly 800us wide glitch as 3.3V falls below around 1.7V, if the 0.95V core voltage comes down first (which it does because we have an active discharge on 0.95V, but not on 3.3V). In this case, it's just wide and high enough to cause the BOOST mode line to engage, which takes the BOOST output and ties it to VBUS, which is just enough for the system to think you're powering it back on again. Which is not what you want when powering down. The ultimate fix was to put a heftier pull-down on the BOOST line so that it can't trip the BOOST output into the VBUS. Another option could be more active discharge FETs, but that would require a full board spin and we are already at certification, so we'll stick with the stronger pull-down on BOOST. It seems to be a robust fix in the worst corner cases we can find. The downside is that when powering an external USB device, you are burning an extra 30mW of power overcoming the pull-down, but typically, any external USB devices plugged into Precursor will burn far in excess of that, so the delta should be negligible.
212 lines
8.8 KiB
Rust
212 lines
8.8 KiB
Rust
#![cfg_attr(target_os = "none", no_std)]
|
|
|
|
/// This is the API that other servers use to call the COM. Read this code as if you
|
|
/// are calling these functions inside a different process.
|
|
pub mod api;
|
|
|
|
pub use api::BattStats;
|
|
use api::{Callback, Opcode};
|
|
use xous::{send_message, Error, CID, Message, msg_scalar_unpack};
|
|
use xous_ipc::{String, Buffer};
|
|
use num_traits::{ToPrimitive, FromPrimitive};
|
|
|
|
/// mapping of the callback function to the library user
|
|
/// this exists in the library user's memory space, so we can have up to one
|
|
/// callback per library user.
|
|
static mut BATTSTATS_CB: Option<fn(BattStats)> = None;
|
|
|
|
/// handles callback messages from the COM server, in the library user's process space.
|
|
fn battstats_server(sid0: usize, sid1: usize, sid2: usize, sid3: usize) {
|
|
let sid = xous::SID::from_u32(sid0 as u32, sid1 as u32, sid2 as u32, sid3 as u32);
|
|
loop {
|
|
let msg = xous::receive_message(sid).unwrap();
|
|
match FromPrimitive::from_usize(msg.body.id()) {
|
|
Some(Callback::BattStats) => msg_scalar_unpack!(msg, lo, hi, _, _, {
|
|
let bs: BattStats = [lo, hi].into();
|
|
unsafe {
|
|
if let Some(cb) = BATTSTATS_CB {
|
|
cb(bs)
|
|
}
|
|
}
|
|
}),
|
|
Some(Callback::Drop) => {
|
|
break; // this exits the loop and kills the thread
|
|
}
|
|
None => (),
|
|
}
|
|
}
|
|
xous::destroy_server(sid).unwrap();
|
|
}
|
|
#[derive(Debug)]
|
|
pub struct Com {
|
|
conn: CID,
|
|
battstats_sid: Option<xous::SID>,
|
|
ticktimer: ticktimer_server::Ticktimer,
|
|
}
|
|
impl Com {
|
|
pub fn new(xns: &xous_names::XousNames) -> Result<Self, xous::Error> {
|
|
let conn = xns.request_connection_blocking(api::SERVER_NAME_COM).expect("Can't connect to COM server");
|
|
Ok(Com {
|
|
conn,
|
|
battstats_sid: None,
|
|
ticktimer: ticktimer_server::Ticktimer::new().expect("Can't connect to ticktimer"),
|
|
})
|
|
}
|
|
|
|
pub fn power_off_soc(&self) -> Result<(), xous::Error> {
|
|
send_message(self.conn,
|
|
Message::new_scalar(Opcode::PowerOffSoc.to_usize().unwrap(), 0, 0, 0, 0)
|
|
).map(|_| ())
|
|
}
|
|
|
|
/// ship mode is synchronous, so that we can schedule order-of-operation dependent tasks around it
|
|
pub fn ship_mode(&self) -> Result<(), xous::Error> {
|
|
let response = send_message(self.conn,
|
|
Message::new_blocking_scalar(Opcode::ShipMode.to_usize().unwrap(), 0, 0, 0, 0))?;
|
|
if let xous::Result::Scalar1(_) = response {
|
|
Ok(())
|
|
} else {
|
|
log::error!("ship_mode failed to execute");
|
|
Err(xous::Error::InternalError)
|
|
}
|
|
}
|
|
|
|
pub fn get_wf200_fw_rev(&self) -> Result<(u8, u8, u8), xous::Error> {
|
|
let response = send_message(self.conn,
|
|
Message::new_blocking_scalar(Opcode::Wf200Rev.to_usize().unwrap(), 0, 0, 0, 0))?;
|
|
if let xous::Result::Scalar1(rev) = response {
|
|
Ok(((rev >> 16) as u8, (rev >> 8) as u8, rev as u8))
|
|
} else {
|
|
panic!("unexpected return value: {:#?}", response);
|
|
}
|
|
}
|
|
|
|
pub fn get_ec_git_rev(&self) -> Result<(u32, bool), Error> {
|
|
let response = send_message(self.conn,
|
|
Message::new_blocking_scalar(Opcode::EcGitRev.to_usize().unwrap(), 0, 0, 0, 0))?;
|
|
if let xous::Result::Scalar2(rev, dirty) = response {
|
|
let dirtybool: bool;
|
|
if dirty == 0 {
|
|
dirtybool = false;
|
|
} else {
|
|
dirtybool = true;
|
|
}
|
|
Ok((rev as u32, dirtybool))
|
|
} else {
|
|
panic!("unexpected return value: {:#?}", response);
|
|
}
|
|
}
|
|
|
|
pub fn send_pds_line(&self, s: &String<512>) -> Result<(), Error> {
|
|
use core::fmt::Write;
|
|
let mut clone_s: String<512> = String::new();
|
|
write!(clone_s, "{}", s.as_str().unwrap()).map_err(|_| xous::Error::AccessDenied)?;
|
|
|
|
let buf = Buffer::into_buf(clone_s).or(Err(xous::Error::InternalError))?;
|
|
buf.lend(
|
|
self.conn,
|
|
Opcode::Wf200PdsLine.to_u32().unwrap()
|
|
).map(|_| ())
|
|
}
|
|
|
|
/// this kicks off an async callback for battery status at some later time
|
|
pub fn req_batt_stats(&self) -> Result<(), xous::Error> {
|
|
send_message(self.conn, Message::new_scalar(Opcode::BattStatsNb.to_usize().unwrap(), 0, 0, 0, 0,)).map(|_| ())
|
|
}
|
|
|
|
/// this allows the caller to provide a hook to handle the callback
|
|
pub fn hook_batt_stats(&mut self, cb: fn(BattStats)) -> Result<(), xous::Error> {
|
|
if unsafe{BATTSTATS_CB}.is_some() {
|
|
return Err(xous::Error::MemoryInUse)
|
|
}
|
|
unsafe{BATTSTATS_CB = Some(cb)};
|
|
if self.battstats_sid.is_none() {
|
|
let sid = xous::create_server().unwrap();
|
|
self.battstats_sid = Some(sid);
|
|
let sid_tuple = sid.to_u32();
|
|
xous::create_thread_4(battstats_server, sid_tuple.0 as usize, sid_tuple.1 as usize, sid_tuple.2 as usize, sid_tuple.3 as usize).unwrap();
|
|
xous::send_message(self.conn,
|
|
Message::new_scalar(Opcode::RegisterBattStatsListener.to_usize().unwrap(),
|
|
sid_tuple.0 as usize, sid_tuple.1 as usize, sid_tuple.2 as usize, sid_tuple.3 as usize
|
|
)).unwrap();
|
|
}
|
|
Ok(())
|
|
}
|
|
|
|
pub fn wifi_disable(&self) -> Result<(), xous::Error> {
|
|
send_message(self.conn, Message::new_scalar(Opcode::Wf200Disable.to_usize().unwrap(), 0, 0, 0, 0,)).map(|_| ())
|
|
}
|
|
// as wifi_reset() re-initializes the wifi chip, call this after wifi_disable() to re-enable wifi
|
|
pub fn wifi_reset(&self) -> Result<(), xous::Error> {
|
|
send_message(self.conn, Message::new_scalar(Opcode::Wf200Reset.to_usize().unwrap(), 0, 0, 0, 0,)).expect("couldn't send reset opcode");
|
|
self.ticktimer.sleep_ms(2000).expect("failed in waiting for wifi chip to reset");
|
|
Ok(())
|
|
}
|
|
pub fn set_ssid_scanning(&self, enable: bool) -> Result<(), xous::Error> {
|
|
if enable {
|
|
send_message(self.conn, Message::new_scalar(Opcode::ScanOn.to_usize().unwrap(), 0, 0, 0, 0,)).map(|_| ())
|
|
} else {
|
|
send_message(self.conn, Message::new_scalar(Opcode::ScanOff.to_usize().unwrap(), 0, 0, 0, 0,)).map(|_| ())
|
|
}
|
|
}
|
|
pub fn ssid_scan_updated(&self) -> Result<bool, xous::Error> {
|
|
if let xous::Result::Scalar1(avail) =
|
|
send_message(self.conn, Message::new_blocking_scalar(Opcode::SsidCheckUpdate.to_usize().unwrap(), 0, 0, 0, 0)).unwrap() {
|
|
if avail != 0 {
|
|
Ok(true)
|
|
} else {
|
|
Ok(false)
|
|
}
|
|
} else {
|
|
Err(xous::Error::InternalError)
|
|
}
|
|
}
|
|
pub fn ssid_fetch_as_string(&self) -> Result<xous_ipc::String::<256>, xous::Error> {
|
|
let ssid_list = xous_ipc::String::<256>::new();
|
|
let mut buf = Buffer::into_buf(ssid_list).or(Err(xous::Error::InternalError))?;
|
|
buf.lend_mut(self.conn, Opcode::SsidFetchAsString.to_u32().unwrap()).or(Err(xous::Error::InternalError))?;
|
|
let response = buf.to_original::<xous_ipc::String::<256>, _>().unwrap();
|
|
Ok(response)
|
|
}
|
|
|
|
pub fn get_standby_current(&self) -> Result<Option<i16>, xous::Error> {
|
|
if let xous::Result::Scalar2(valid, current) =
|
|
send_message(self.conn, Message::new_blocking_scalar(Opcode::StandbyCurrent.to_usize().unwrap(), 0, 0, 0, 0)).unwrap() {
|
|
if valid != 0 {
|
|
Ok(Some(current as i16))
|
|
} else {
|
|
Ok(None)
|
|
}
|
|
} else {
|
|
Err(xous::Error::InternalError)
|
|
}
|
|
}
|
|
|
|
pub fn set_boost(&self, on: bool) -> Result<(), xous::Error> {
|
|
if on {
|
|
send_message(self.conn, Message::new_scalar(Opcode::BoostOn.to_usize().unwrap(), 0, 0, 0, 0,)).map(|_| ())
|
|
} else {
|
|
send_message(self.conn, Message::new_scalar(Opcode::BoostOff.to_usize().unwrap(), 0, 0, 0, 0,)).map(|_| ())
|
|
}
|
|
}
|
|
// note to future self: add other event listener registrations (such as network events) here
|
|
}
|
|
|
|
impl Drop for Com {
|
|
fn drop(&mut self) {
|
|
// if we have callbacks, destroy the battstats callback server
|
|
if let Some(sid) = self.battstats_sid.take() {
|
|
// no need to tell the COM server we're quitting: the next time a callback processes,
|
|
// it will automatically remove my entry as it will receive a ServerNotFound error.
|
|
|
|
// tell my handler thread to quit
|
|
let cid = xous::connect(sid).unwrap();
|
|
xous::send_message(cid,
|
|
Message::new_scalar(api::Callback::Drop.to_usize().unwrap(), 0, 0, 0, 0)).unwrap();
|
|
unsafe{xous::disconnect(cid).unwrap();}
|
|
}
|
|
|
|
// now de-allocate myself. It's unsafe because we are responsible to make sure nobody else is using the connection.
|
|
unsafe{xous::disconnect(self.conn).unwrap();}
|
|
}
|
|
}
|