I wrote in a commit yesterday how there was no ROI on doing this
yet somehow I kept on doing it. I blame poor impulse control.
Turns out there was a series of race conditions and bugs that
caused this thing to "mostly work" on the first go at it but
really hard to debug and get very right.
1. Litex UART has a weird undocumented API. You advance the Rx
FIFO by writing `1` to the PENDING bit, and no other way. However,
you determine if there are any more characters to receive by
reading the EMPTY bit and seeing if it is 1. The previous method
wrote `1` to the PENDING bit and then used the PENDING bit to
see if a character was available, under the theory that the
PENDING bit would be set again if there was still a character.
This is somewhat true, except that the PENDING bit is set only
some amount of time later which is about comparable to a few
CPU instructions, so if you had a fast loop path the PENDING
bit would show as cleared and you'd exit, which would cause
no further interrupts to fire because the interrupt was
effecitvely not acknowledged.
This isn't written up anywhere but I figured this out by
just reading the source code for Litex UART and BIOS:
e8be391504/litex/soc/cores/uart.py (L264-L279)ccd3ab17be/litex/soc/software/libbase/uart.c (L38-L44)
2. I had the Key Injector IP block in the `sys` domain, which
would have its clock cut when the CPU went to sleep, which would
cause input characters to disappear when the CPU went into power
saving. moving this to "always on" domain fixes that.
3. I had the UART PHY in the always on block (so you could
send or receive exactly one character), but not the
separate UART block (which contained the FIFOs).
The UART block would also go into power
savings, and this would cause FIFO entries to go missing.
4. Escape sequences get sent as a burst of characters. The Key Injector
originally did not have a FIFO of its own, so it would only
remember the *last* key of the sequence that was written, causing
some keys to be dropped occassionally. Adding a 16-deep FIFO
to the injector fixes this.
5. The code I had to read out the injector's results was designed with
the "strobe" bit (to indicate that the FIFO had characters) in the
same regsiter as the character itself. Thus the loop that 1. checked
if the fifo was empty then 2. read and forwarded the character
would actually perform two reads from the FIFO. However, this "mostly worked"
I think because the FIFO retains the last value that was written
even when it was empty, so if only one character was read at a time
everything was fine. It only didn't work when you stuffed two characters
in there, as you'd drop the first one. Reading the FIFO once and
then interpreting the code with a bitmask fixes this.
6. The escape sequences, in their full glory with no dropped characters,
required a refactored parsing routine, which I have now added.
7. backspace->delete mappings, the bane of computer engineers since 1960.
OK. very bald yak. Here I lay down the shears next to several
mooshi pillows stuffed with the finest Yak hair.
Always reset the EC on boot. If we have a cold-boot situation,
it's hard to know what state the EC is in versus our stack;
a hard reset on the EC guarantees we at least always start from
the same point.
Note that on suspend/resume, there is no reset - the EC continues
trundling onwards, but the system was designed for this.
This is not the fix I was hoping for for connection stability,
but unfortunately this is where we are at.
The problem is that at some point the WF200 throws a "host interface
error"; but the error codes show no specific error. After throwing
this error, it can respond to some basic commands (such as the one
asking what the current status and error codes are), but higher level
APIs seem to time out. There's no command to bring the WF200 stack
to a sane state (like a warm reset or buffer flush) as far as I
can see, so, the solution is to detect the issue and send a reset
to the WF200. This keeps the link up in the long term, but
you will experience drop-outs about once every 2-3 hours for
about 20 seconds while the system detects and fixes the problem.
I think for this one, more data will be needed from customer units
to see if this could be just a local network issue with my config
or a more pervasive problem.
Each Cargo.toml now includes a comment which remnids maintainers
of the dependency policy for Xous (that is, nail down every dependency
to the minor number).
Versions are pinned down to the minor number. Yes, this means that
we don't automatically pull in features and bug updates from crates.io,
but it also means we don't pull in new attack surfaces and code that
hasn't been tested or reviewed. I'd like this process to be very deliberate
and not automatic for Xous.
The `rand` crate is almost pinned down to a single version, except
for an odd dependency that's pulled in by hosted mode that depends
on rand 0.8.4 via a subordinate dependency via the `tempfile` crate.
Pondering if it's worth it to try and eliminate that, because the
0.8.4 version doesn't get compiled into any version that touches
real hardware. It just makes it harder to analyze the Cargo.lock
file, mostly. I think I'll leave it as-is.
an activity_interval Arc::AtomicU32 is shared between the
connection manager thread and the main net thread. Every
time there is a packet received, the activity interval is
bumped to 0. If two interval polls pass, then a more
expensive wlan_status() call is issued to the COM to see
if we're really still connected.
On a typcial network, the ARP traffic alone is sufficient
to keep the status timeout from happening. The status interval
is currently set at slightly over 10 seconds, so if you fall
off the network entirely, about 20 seconds will pass before
an automatic rejoin is issued. This can be adjusted by tuning
the POLL_INTERVAL_MS variable inside the net service's
connection_manager.rs module.
much better, but still eventually the stack can fall over eventually.
also, the stack doesn't behave well when you try to initiate new
commands in the middle of a flood, because the back-pressure mechanisms
are primarily in-stack at the moment.
I think i have an idea on how to fix that but this will have to be later.
- moved most ping state into the Net crate proper, since the smoltcp
implementation assumes a tightly bound set of objects and lifetimes
in its icmp abstraction
- created various convenience abstractions for handling single and
multiple pings, blocking and non-blocking.
- refactored the "net" command to use the new form
Initial testing indicates there are still some bugs (seems to be
with the way we are handling timestamping and doing pong retirement)
but at least we're not getting tons of async callback errors like
we were before, and we're not shuttling obscene amounts of state
using Arc-Mutex between the input and output of the ping operations.
Now that I understand how smoltcp does ping better I have regrets.
The demo example in smoltcp uses a funky macro that was a bit
misleading. I have gotten rid of that but I probably would have made
different decisions in implementing this had I understood the API better.
Anyways. It works, but has some trouble handling the cases of timeouts
sometimes.
not fully working yet, but the architecture is there and it builds.
smoltcp's ping implementation (or at least its demo code) was not
very amenable to splitting into modules, had to recode most of it.
the ipv6 is still a hack.
Multicast/Broadcast is not supported by smoltcp it seems, so those
calls are just unimplemented. But we are able to clone UdpSocket,
for the sick puppies who like to do that sort of thing.