Always reset the EC on boot. If we have a cold-boot situation,
it's hard to know what state the EC is in versus our stack;
a hard reset on the EC guarantees we at least always start from
the same point.
Note that on suspend/resume, there is no reset - the EC continues
trundling onwards, but the system was designed for this.
This is not the fix I was hoping for for connection stability,
but unfortunately this is where we are at.
The problem is that at some point the WF200 throws a "host interface
error"; but the error codes show no specific error. After throwing
this error, it can respond to some basic commands (such as the one
asking what the current status and error codes are), but higher level
APIs seem to time out. There's no command to bring the WF200 stack
to a sane state (like a warm reset or buffer flush) as far as I
can see, so, the solution is to detect the issue and send a reset
to the WF200. This keeps the link up in the long term, but
you will experience drop-outs about once every 2-3 hours for
about 20 seconds while the system detects and fixes the problem.
I think for this one, more data will be needed from customer units
to see if this could be just a local network issue with my config
or a more pervasive problem.
an activity_interval Arc::AtomicU32 is shared between the
connection manager thread and the main net thread. Every
time there is a packet received, the activity interval is
bumped to 0. If two interval polls pass, then a more
expensive wlan_status() call is issued to the COM to see
if we're really still connected.
On a typcial network, the ARP traffic alone is sufficient
to keep the status timeout from happening. The status interval
is currently set at slightly over 10 seconds, so if you fall
off the network entirely, about 20 seconds will pass before
an automatic rejoin is issued. This can be adjusted by tuning
the POLL_INTERVAL_MS variable inside the net service's
connection_manager.rs module.
much better, but still eventually the stack can fall over eventually.
also, the stack doesn't behave well when you try to initiate new
commands in the middle of a flood, because the back-pressure mechanisms
are primarily in-stack at the moment.
I think i have an idea on how to fix that but this will have to be later.
- moved most ping state into the Net crate proper, since the smoltcp
implementation assumes a tightly bound set of objects and lifetimes
in its icmp abstraction
- created various convenience abstractions for handling single and
multiple pings, blocking and non-blocking.
- refactored the "net" command to use the new form
Initial testing indicates there are still some bugs (seems to be
with the way we are handling timestamping and doing pong retirement)
but at least we're not getting tons of async callback errors like
we were before, and we're not shuttling obscene amounts of state
using Arc-Mutex between the input and output of the ping operations.
Now that I understand how smoltcp does ping better I have regrets.
The demo example in smoltcp uses a funky macro that was a bit
misleading. I have gotten rid of that but I probably would have made
different decisions in implementing this had I understood the API better.
Anyways. It works, but has some trouble handling the cases of timeouts
sometimes.
not fully working yet, but the architecture is there and it builds.
smoltcp's ping implementation (or at least its demo code) was not
very amenable to splitting into modules, had to recode most of it.
the ipv6 is still a hack.
Multicast/Broadcast is not supported by smoltcp it seems, so those
calls are just unimplemented. But we are able to clone UdpSocket,
for the sick puppies who like to do that sort of thing.