Commit graph

17 commits

Author SHA1 Message Date
bunnie
b7c0387186 connection manager: interpret DHCP state before concluding we're connected 2022-02-03 13:37:14 +08:00
bunnie
8f321d540e clean up a spurious dialog box in hosted mode 2022-02-02 23:59:37 +08:00
bunnie
4690075c40 clean build, but...much testing to do. 2022-01-31 04:03:31 +08:00
bunnie
177ad38db2 derive SSID scan on shellchat from the connection manager
The connection manager keeps track of all our SSIDs, not the COM.
2022-01-30 16:53:15 +08:00
bunnie
f7ea782e73 fix some ergonomics around the status bar 2022-01-28 16:28:06 +08:00
bunnie
25bccd9446 THE BALDEST YAK: keyboard injection now working
I wrote in a commit yesterday how there was no ROI on doing this
yet somehow I kept on doing it. I blame poor impulse control.

Turns out there was a series of race conditions and bugs that
caused this thing to "mostly work" on the first go at it but
really hard to debug and get very right.

1. Litex UART has a weird undocumented API. You advance the Rx
FIFO by writing `1` to the PENDING bit, and no other way. However,
you determine if there are any more characters to receive by
reading the EMPTY bit and seeing if it is 1. The previous method
wrote `1` to the PENDING bit and then used the PENDING bit to
see if a character was available, under the theory that the
PENDING bit would be set again if there was still a character.
This is somewhat true, except that the PENDING bit is set only
some amount of time later which is about comparable to a few
CPU instructions, so if you had a fast loop path the PENDING
bit would show as cleared and you'd exit, which would cause
no further interrupts to fire because the interrupt was
effecitvely not acknowledged.

This isn't written up anywhere but I figured this out by
just reading the source code for Litex UART and BIOS:
e8be391504/litex/soc/cores/uart.py (L264-L279)
ccd3ab17be/litex/soc/software/libbase/uart.c (L38-L44)

2. I had the Key Injector IP block in the `sys` domain, which
would have its clock cut when the CPU went to sleep, which would
cause input characters to disappear when the CPU went into power
saving. moving this to "always on" domain fixes that.

3. I had the UART PHY in the always on block (so you could
send or receive exactly one character), but not the
separate UART block (which contained the FIFOs).
The UART block would also go into power
savings, and this would cause FIFO entries to go missing.

4. Escape sequences get sent as a burst of characters. The Key Injector
originally did not have a FIFO of its own, so it would only
remember the *last* key of the sequence that was written, causing
some keys to be dropped occassionally. Adding a 16-deep FIFO
to the injector fixes this.

5. The code I had to read out the injector's results was designed with
the "strobe" bit (to indicate that the FIFO had characters) in the
same regsiter as the character itself. Thus the loop that 1. checked
if the fifo was empty then 2. read and forwarded the character
would actually perform two reads from the FIFO. However, this "mostly worked"
I think because the FIFO retains the last value that was written
even when it was empty, so if only one character was read at a time
everything was fine. It only didn't work when you stuffed two characters
in there, as you'd drop the first one. Reading the FIFO once and
then interpreting the code with a bitmask fixes this.

6. The escape sequences, in their full glory with no dropped characters,
required a refactored parsing routine, which I have now added.

7. backspace->delete mappings, the bane of computer engineers since 1960.

OK. very bald yak. Here I lay down the shears next to several
mooshi pillows stuffed with the finest Yak hair.
2022-01-28 15:17:47 +08:00
bunnie
5a1139a367 move cache flush on susres to just before the suspend event
- also nail down the interrupt handlers from firing from the COM
during suspend
- ensure that connects don't happen while scanning
2022-01-27 22:05:38 +08:00
bunnie
5daf4c4723 suppress connection manager polling when the pddb is not mounted
no point in trying to connect to APs when we have no AP list or keys.
2022-01-27 15:01:19 +08:00
bunnie
5ef7126ede add better handling for wfx HIF err condition 2022-01-27 14:02:28 +08:00
bunnie
3f2f304202 refactor connection manager to be more responsive to suspend/resume 2022-01-27 13:46:43 +08:00
bunnie
4c4ca1577f fix connection manager state machine
seems to work a lot better, but needs a lot more testing
2022-01-27 03:56:39 +08:00
bunnie
94a8a4736f make wlan status checks asynchronous
the synchronous method would lead to stutter in the animation
of the status bar during netork congestion.
2022-01-23 00:24:45 +08:00
bunnie
0cafd10e28 refactor status bar to take advantage of the new fonts 2022-01-22 18:25:39 +08:00
bunnie
fbd0bc542f detect when the WF200 goes catatonic and reset it
This is not the fix I was hoping for for connection stability,
but unfortunately this is where we are at.

The problem is that at some point the WF200 throws a "host interface
error"; but the error codes show no specific error. After throwing
this error, it can respond to some basic commands (such as the one
asking what the current status and error codes are), but higher level
APIs seem to time out. There's no command to bring the WF200 stack
to a sane state (like a warm reset or buffer flush) as far as I
can see, so, the solution is to detect the issue and send a reset
to the WF200. This keeps the link up in the long term, but
you will experience drop-outs about once every 2-3 hours for
about 20 seconds while the system detects and fixes the problem.

I think for this one, more data will be needed from customer units
to see if this could be just a local network issue with my config
or a more pervasive problem.
2022-01-15 15:13:51 +08:00
bunnie
4f9374e860 add enhanced debugging to the COM for wf200 2022-01-14 15:27:24 +08:00
bunnie
a4bb889a5d update wlan status to a binary version with more detailed output 2022-01-14 02:23:57 +08:00
bunnie
744d6ae091 reduce system workload checking network connection state
an activity_interval Arc::AtomicU32 is shared between the
connection manager thread and the main net thread. Every
time there is a packet received, the activity interval is
bumped to 0. If two interval polls pass, then a more
expensive wlan_status() call is issued to the COM to see
if we're really still connected.

On a typcial network, the ARP traffic alone is sufficient
to keep the status timeout from happening. The status interval
is currently set at slightly over 10 seconds, so if you fall
off the network entirely, about 20 seconds will pass before
an automatic rejoin is issued. This can be adjusted by tuning
the POLL_INTERVAL_MS variable inside the net service's
connection_manager.rs module.
2022-01-09 14:03:20 +08:00