smoltcp requires some polling to be done in the future for it
to work with low latency. It returns a time in the future for
the next poll.
This refactors the polling algorithm to:
1. use a fixed thread pool. This burns a little extra memory in
exchange for not having to allocate/de-allocate threads every
time a follow-up is needed.
2. use a short/long scheduler, where short delays (shorter than
the scheduler quantum) are grouped together, and only a single
follow-up is fired off within that time range if needed. Longer
delays have a larger window (roughly +/- 100ms) of grouping,
so fewer such events are also required in the distant future.
Empirically the delays seem to fall into two groups, either "short"
(less than 20ms) or "long" (around 700ms).
This improved scheduler uses fewer threads and generates less
messages, so instead of 16 threads and encountering exhaustion
we have 9 and have yet to see more than 7 used even under the
most strenuous tests (multiple while-true curl loops + fountain
test + ping simultaneously).
Some helpful debug is also printed now when scheduler runs out
of slots, so we can see the distribution of pending delays.
we no longer create a new interface on net reset, which means that
the socket handles don't blow up if we change IP addresses.
However, the ARP cache is still stale and there seems to be on way
to force it to flush....but I guess in theory, eventually it
should fix itself, if smoltcp is working correctly?
the refactor changes the way sockets are handled, so now, when
the interface is rebound we are certain to get panics.
working on resolving this detail now, but at least the interface
is working now and it seems more stable than before.
total threads in the net crate are around 10 right now, 32 max, so
increasing the sleeping thread limit to 16, since every now and then
we get exhaustion notes.
Due to overly liberal use of `.take()`, file handles were getting closed
when doing ordinary operations. This stops that.
Signed-off-by: Sean Cross <sean@xobs.io>
This now adds a `timeout` parameter to the connect() API call.
Additionally, connections will not be returned until they are determined
to be open, or until an error occurs (such as a timeout).
Signed-off-by: Sean Cross <sean@xobs.io>
It's not a good time to bug the EC to do network stuff when it's updating
itself.
...might even want to send the network into a disconnected state,
but, let's start with just turning off the connection manager
for now.
Spent a couple hours chasing down a "bug" which is acutally just
something about how http works that I don't understand. TCP was
working just fine but there is ... idk some sort of keep alive
thing that occupies a socket so the "web server" blocks waiting
for a read. Anyways, I guess the "right" way to solve that would
be to make a multi-threaded web server
OH GOD STOP
right. it's just a demo to prove that TCP works. done.
Open an issue if you find a problem with TCP kthx!
Good enough so that if you type `net server` and you hit the IP
address of the device, it'll respond with something like
Hello from Precursor!
I have been up for 86087 ms.
There's still all kinds of bugs, I'm sure. But ... I'm also not
sure /why/ you would want a web server on Precursor. This is more
just to make sure that the TCP stack isn't totally broken.
The "web server" as it may be is quite broken and doesn't parse
any headers and probably sends a bogus amount of data because
I can't figure out if the content length includes some new lines
or not. But really, this just isn't in scope. Works with Chrome,
Firefox shows the status page and then says "connection reset" and hides
all the information. Whatever, browser compatibility is well beyond
my pay grade!
I wrote in a commit yesterday how there was no ROI on doing this
yet somehow I kept on doing it. I blame poor impulse control.
Turns out there was a series of race conditions and bugs that
caused this thing to "mostly work" on the first go at it but
really hard to debug and get very right.
1. Litex UART has a weird undocumented API. You advance the Rx
FIFO by writing `1` to the PENDING bit, and no other way. However,
you determine if there are any more characters to receive by
reading the EMPTY bit and seeing if it is 1. The previous method
wrote `1` to the PENDING bit and then used the PENDING bit to
see if a character was available, under the theory that the
PENDING bit would be set again if there was still a character.
This is somewhat true, except that the PENDING bit is set only
some amount of time later which is about comparable to a few
CPU instructions, so if you had a fast loop path the PENDING
bit would show as cleared and you'd exit, which would cause
no further interrupts to fire because the interrupt was
effecitvely not acknowledged.
This isn't written up anywhere but I figured this out by
just reading the source code for Litex UART and BIOS:
e8be391504/litex/soc/cores/uart.py (L264-L279)ccd3ab17be/litex/soc/software/libbase/uart.c (L38-L44)
2. I had the Key Injector IP block in the `sys` domain, which
would have its clock cut when the CPU went to sleep, which would
cause input characters to disappear when the CPU went into power
saving. moving this to "always on" domain fixes that.
3. I had the UART PHY in the always on block (so you could
send or receive exactly one character), but not the
separate UART block (which contained the FIFOs).
The UART block would also go into power
savings, and this would cause FIFO entries to go missing.
4. Escape sequences get sent as a burst of characters. The Key Injector
originally did not have a FIFO of its own, so it would only
remember the *last* key of the sequence that was written, causing
some keys to be dropped occassionally. Adding a 16-deep FIFO
to the injector fixes this.
5. The code I had to read out the injector's results was designed with
the "strobe" bit (to indicate that the FIFO had characters) in the
same regsiter as the character itself. Thus the loop that 1. checked
if the fifo was empty then 2. read and forwarded the character
would actually perform two reads from the FIFO. However, this "mostly worked"
I think because the FIFO retains the last value that was written
even when it was empty, so if only one character was read at a time
everything was fine. It only didn't work when you stuffed two characters
in there, as you'd drop the first one. Reading the FIFO once and
then interpreting the code with a bitmask fixes this.
6. The escape sequences, in their full glory with no dropped characters,
required a refactored parsing routine, which I have now added.
7. backspace->delete mappings, the bane of computer engineers since 1960.
OK. very bald yak. Here I lay down the shears next to several
mooshi pillows stuffed with the finest Yak hair.
Always reset the EC on boot. If we have a cold-boot situation,
it's hard to know what state the EC is in versus our stack;
a hard reset on the EC guarantees we at least always start from
the same point.
Note that on suspend/resume, there is no reset - the EC continues
trundling onwards, but the system was designed for this.