It's not a good time to bug the EC to do network stuff when it's updating
itself.
...might even want to send the network into a disconnected state,
but, let's start with just turning off the connection manager
for now.
Spent a couple hours chasing down a "bug" which is acutally just
something about how http works that I don't understand. TCP was
working just fine but there is ... idk some sort of keep alive
thing that occupies a socket so the "web server" blocks waiting
for a read. Anyways, I guess the "right" way to solve that would
be to make a multi-threaded web server
OH GOD STOP
right. it's just a demo to prove that TCP works. done.
Open an issue if you find a problem with TCP kthx!
Good enough so that if you type `net server` and you hit the IP
address of the device, it'll respond with something like
Hello from Precursor!
I have been up for 86087 ms.
There's still all kinds of bugs, I'm sure. But ... I'm also not
sure /why/ you would want a web server on Precursor. This is more
just to make sure that the TCP stack isn't totally broken.
The "web server" as it may be is quite broken and doesn't parse
any headers and probably sends a bogus amount of data because
I can't figure out if the content length includes some new lines
or not. But really, this just isn't in scope. Works with Chrome,
Firefox shows the status page and then says "connection reset" and hides
all the information. Whatever, browser compatibility is well beyond
my pay grade!
Was doing disjoint loads and stores on an Atomic, really, should
be using the fetch_add, fetch_sub variants to be proper.
Didn't seem to impact anything but maybe there's a future version
of me that high fives me for doing this.
Still not there....to get it reporting in a user-visible fashion
I'm realizing I'm going to have to build a dedicated facility in
Xous to track this because otherwise I have to trigger the
automatic rebuild of a "heavy" program that would naturally
encapsulate such information.
Maybe for now, though, at least over the serial port I can
get a somewhat relevant string???
this prevents us from having to use the entire reserved region
as a worst-case and improves screen-up time on resume.
previously, we didn't encode a signed length in the kernel so we couldn't
trust the length that was presented to us. This was fixed a while ago
but i just connected the dots today that this needed to be updated as well.
I wrote in a commit yesterday how there was no ROI on doing this
yet somehow I kept on doing it. I blame poor impulse control.
Turns out there was a series of race conditions and bugs that
caused this thing to "mostly work" on the first go at it but
really hard to debug and get very right.
1. Litex UART has a weird undocumented API. You advance the Rx
FIFO by writing `1` to the PENDING bit, and no other way. However,
you determine if there are any more characters to receive by
reading the EMPTY bit and seeing if it is 1. The previous method
wrote `1` to the PENDING bit and then used the PENDING bit to
see if a character was available, under the theory that the
PENDING bit would be set again if there was still a character.
This is somewhat true, except that the PENDING bit is set only
some amount of time later which is about comparable to a few
CPU instructions, so if you had a fast loop path the PENDING
bit would show as cleared and you'd exit, which would cause
no further interrupts to fire because the interrupt was
effecitvely not acknowledged.
This isn't written up anywhere but I figured this out by
just reading the source code for Litex UART and BIOS:
e8be391504/litex/soc/cores/uart.py (L264-L279)ccd3ab17be/litex/soc/software/libbase/uart.c (L38-L44)
2. I had the Key Injector IP block in the `sys` domain, which
would have its clock cut when the CPU went to sleep, which would
cause input characters to disappear when the CPU went into power
saving. moving this to "always on" domain fixes that.
3. I had the UART PHY in the always on block (so you could
send or receive exactly one character), but not the
separate UART block (which contained the FIFOs).
The UART block would also go into power
savings, and this would cause FIFO entries to go missing.
4. Escape sequences get sent as a burst of characters. The Key Injector
originally did not have a FIFO of its own, so it would only
remember the *last* key of the sequence that was written, causing
some keys to be dropped occassionally. Adding a 16-deep FIFO
to the injector fixes this.
5. The code I had to read out the injector's results was designed with
the "strobe" bit (to indicate that the FIFO had characters) in the
same regsiter as the character itself. Thus the loop that 1. checked
if the fifo was empty then 2. read and forwarded the character
would actually perform two reads from the FIFO. However, this "mostly worked"
I think because the FIFO retains the last value that was written
even when it was empty, so if only one character was read at a time
everything was fine. It only didn't work when you stuffed two characters
in there, as you'd drop the first one. Reading the FIFO once and
then interpreting the code with a bitmask fixes this.
6. The escape sequences, in their full glory with no dropped characters,
required a refactored parsing routine, which I have now added.
7. backspace->delete mappings, the bane of computer engineers since 1960.
OK. very bald yak. Here I lay down the shears next to several
mooshi pillows stuffed with the finest Yak hair.
just couldn't let it go. figured out the issue is a race condition
in how the Litex UARTs are constructed...I don't know how Litex
normally handles this kind of situation but they have this funky
construction where reading the fifo doesn't advance it, you have
to...clear the pending bit. I think it was meant to be a "clever"
thing that saves an instruction or something like that since you
always have to clear the pending bit.
Anyways, the previous incarnation of this loop checked to see
if the pending bit was set again and if it was it'd run back
and fetch another character. This turns out to be a bad idea
because the pending bit goes through a multireg and other stuff
before it's readable which means it has a lot of delay on it.
This leads to a race condition.
This version actually checks if the fifo is empty and if it isn't,
it reads the character *and* pumps the pending bit (because
the FIFO doesn't auto-advance when you read it, you have to clear
the pending bit).
This works a lot better, but it's not at all well documented how
this works and it's very hard to tell from reading the source code
because it's written using really fancy migen abstractions that
are also poorly documented and have a lot of cursed constructions.
Anyways. At least the console doesn't die now when you type
a control character, *but* you do have the problem that the
escape codes get mis-interpreted sometimes. If it really really
becomes important later on to fix that it would involve tracing
out the sequence of keys that arrive at InjectKey and figuring
out if things are coming out of order or what is triggering the
bad escape codes.
there is still some mysterious problem involving a race condition
of the raw hardware console UART Rx path deciding it doesn't want
to report new characters anymore to the interrupt handler that
is triggered when multi-byte sequences are shoved down the
pipe. So long as you're typing simple commands it's fine, but
escape sequences tend to lock things up. I don't think there's
enough ROI to continue investigating this facility.
We run a branch of minifb because we need the `set_key_state`
function, which is not available on the main branch. This
function is necessary to extract raw scan keycodes from the
keyboard so we can respond to e.g. menu and prediction emulation
keys (Home and Fn keys). The mainline minifb crate eats all
of those key events and does not pass them on.
the re-regsitration is a "send" not a "lend" now, because
the imef can't block during the context switch.
Not sure why I made it a lend in the first place, probably just
wasn't thinking...
only cone connection is allowed to the IMEF anyways, because
the GAM does traffic control on who has authorization to access it.
So, no need for multi-callback support. Saves a tiny bit of RAM.
request_focus is "dangerous" because any random server could
request a UX context to pop up. There is a checked version
that requires a GAM token that should be used, but, this leaves
the question of how does the initial app that's supposed to be
focused gets set.
A small mod to the UxRegistration call is made to check for
the name of the default focus app, and when it is seen, a thread
is fired off to request focus for that app. That allows us
to deprecate this otherwise dangerous call.
trust levels now default to a mid-level, with the password
modals explicitly tested for by the Context logic (the idea
being to deny any untrusted canvases the ability to render
inverted text).
ball bounce app also basically works, and context
switching between the bounce app and the main menu
is working too.
The first "app" is just going to be a whole-framebuffer
demo that gets raw keys and does some stuff on the screen.
It's the starting point if you wanted to eg. write a simple
video game or something for the device, but you didn't care
about much of the other UX sugar.
Really clear up the roles and structures of word wrapping.
Significantly, we have now figured out that the word wrapper
should be the word wrapper, and that the text bounds should
be computed by a text bounds computation.
Conflating flexible text bounds with word wrapping makes
the math really hard.
So, the word wrapper always works with a bounding area starting
at 0,0, and will wrap until it hits a Point designated as its
absolute max bounds.
The returned typeset block is referenced to 0,0, and then it
is shifted to the correct location by the rendering function.
This externalizes the computation of the final location plus
the rendering bounds to the outer functions that need to care
about this, thus simplifying the word wrapper significantly.
this just grafts in the new crate, while leaving the old crate
unscathed. once this is somewhat functional we'll excise the old
crate and reformat the loader for the "hard binary" image of
the fonts.
Always reset the EC on boot. If we have a cold-boot situation,
it's hard to know what state the EC is in versus our stack;
a hard reset on the EC guarantees we at least always start from
the same point.
Note that on suspend/resume, there is no reset - the EC continues
trundling onwards, but the system was designed for this.
This is not the fix I was hoping for for connection stability,
but unfortunately this is where we are at.
The problem is that at some point the WF200 throws a "host interface
error"; but the error codes show no specific error. After throwing
this error, it can respond to some basic commands (such as the one
asking what the current status and error codes are), but higher level
APIs seem to time out. There's no command to bring the WF200 stack
to a sane state (like a warm reset or buffer flush) as far as I
can see, so, the solution is to detect the issue and send a reset
to the WF200. This keeps the link up in the long term, but
you will experience drop-outs about once every 2-3 hours for
about 20 seconds while the system detects and fixes the problem.
I think for this one, more data will be needed from customer units
to see if this could be just a local network issue with my config
or a more pervasive problem.
This moves the kernel into the main monorepo, allowing it to share
packages with the rest of the system. This change will allow us to
reduce the number of rebuilds that take place, as well as reducing disk
usage.
Note that the loader is still an indepenent project, and the integration
of that into the monorepo is pending.
Signed-off-by: Sean Cross <sean@xobs.io>
- code is merged into shellchat so there's less alignment overhead
and some library reuse
- server is not spawned until it's needed, so the RAM load is less
Saves a bit on resources and the RTC crate doesn't need
to be stand-alone now that the modals crate is a thing;
we are able to split the UX routine to manage the RTC out
of the code that actually manages the hardware.
The hardware code ended up in LLIO, and the UX ended up in the status
routine.
Each Cargo.toml now includes a comment which remnids maintainers
of the dependency policy for Xous (that is, nail down every dependency
to the minor number).
Versions are pinned down to the minor number. Yes, this means that
we don't automatically pull in features and bug updates from crates.io,
but it also means we don't pull in new attack surfaces and code that
hasn't been tested or reviewed. I'd like this process to be very deliberate
and not automatic for Xous.
The `rand` crate is almost pinned down to a single version, except
for an odd dependency that's pulled in by hosted mode that depends
on rand 0.8.4 via a subordinate dependency via the `tempfile` crate.
Pondering if it's worth it to try and eliminate that, because the
0.8.4 version doesn't get compiled into any version that touches
real hardware. It just makes it harder to analyze the Cargo.lock
file, mostly. I think I'll leave it as-is.
So far it's been no problem to suspend these in any order, but as
more services come to rely upon them it's better if they suspend after
any client applications have been suspended.
an activity_interval Arc::AtomicU32 is shared between the
connection manager thread and the main net thread. Every
time there is a packet received, the activity interval is
bumped to 0. If two interval polls pass, then a more
expensive wlan_status() call is issued to the COM to see
if we're really still connected.
On a typcial network, the ARP traffic alone is sufficient
to keep the status timeout from happening. The status interval
is currently set at slightly over 10 seconds, so if you fall
off the network entirely, about 20 seconds will pass before
an automatic rejoin is issued. This can be adjusted by tuning
the POLL_INTERVAL_MS variable inside the net service's
connection_manager.rs module.