I did observe some PDDB corruption that happened today that looks
ostensibly linked to a record that didn't sync up with the disk,
so, let's be safer and sync everything. We can work on optimizing
performance after correctness is guaranteed.
The problem with the current is_mounted() call is that it blocks
while the PDDB is requesting a password or actively formatting
(otherwise it doesn't block). It's actually just...partially blocking.
That doesn't cut it for libstd-linked system services that need to run but
before the PDDB comes up. In particular, we need to be able to respond
to time queries *somehow*, even before our timezone and offsets are
loaded from the PDDB.
I considered doing a callback mechanism for mounting, but this
is kind of complex and probably not worth it. Instead, a separate
thread that can return the value of a single boolean revealing
the mount state of the PDDB is created, and you can create an
object that's capable of inspecting that boolean.
the u64 in and of itself is meaningless, without the context
from the PDDB that adds the offset to wall clock time plus
time zone. This is glued together by the time.rs stub inside
the status service.
This will create a 100MiB file in tools/ppdb-images/hosted.bin
(sorry!!) which is persistent storage for hosted mode.
Delete the file if you want to start over from scratch.
It's...pretty brittle. I expect problems, but maybe it will at
least get things moving.
Due to overly liberal use of `.take()`, file handles were getting closed
when doing ordinary operations. This stops that.
Signed-off-by: Sean Cross <sean@xobs.io>
This now adds a `timeout` parameter to the connect() API call.
Additionally, connections will not be returned until they are determined
to be open, or until an error occurs (such as a timeout).
Signed-off-by: Sean Cross <sean@xobs.io>
this will disconnect the battery and put the device in a very low power
state, and you can only power it back on again by plugging it into