Commit graph

2 commits

Author SHA1 Message Date
Sean Cross
ed4dfd4dc1 emulation: com: update HOLD as part of Transmit
Previously, the HOLD signal was updated in a different clock domain from
the transmission signal. This could result in the HOLD bit being set
even if there was no data available.

Update the HOLD bit if it's present as part of the Transmit cycle.

Signed-off-by: Sean Cross <sean@xobs.io>
2022-02-14 13:52:43 +08:00
Sean Cross
49e1eb19c0 emulation: connect EC
Connect the EC to the SoC. This allows for emulating both the EC and SoC
in tandem. Messages flow via a 16-bit bus. When data is not available,
`0xdddd` is returned.

There is a HOLD line that goes from the EC to the SoC. This is tied to
the inverse of presence of data in the EC FIFO -- when it's empty, HOLD
is `1`, and when there is data it's `0`.

Signed-off-by: Sean Cross <sean@xobs.io>
2022-02-14 12:28:40 +08:00