This is not the fix I was hoping for for connection stability,
but unfortunately this is where we are at.
The problem is that at some point the WF200 throws a "host interface
error"; but the error codes show no specific error. After throwing
this error, it can respond to some basic commands (such as the one
asking what the current status and error codes are), but higher level
APIs seem to time out. There's no command to bring the WF200 stack
to a sane state (like a warm reset or buffer flush) as far as I
can see, so, the solution is to detect the issue and send a reset
to the WF200. This keeps the link up in the long term, but
you will experience drop-outs about once every 2-3 hours for
about 20 seconds while the system detects and fixes the problem.
I think for this one, more data will be needed from customer units
to see if this could be just a local network issue with my config
or a more pervasive problem.
an activity_interval Arc::AtomicU32 is shared between the
connection manager thread and the main net thread. Every
time there is a packet received, the activity interval is
bumped to 0. If two interval polls pass, then a more
expensive wlan_status() call is issued to the COM to see
if we're really still connected.
On a typcial network, the ARP traffic alone is sufficient
to keep the status timeout from happening. The status interval
is currently set at slightly over 10 seconds, so if you fall
off the network entirely, about 20 seconds will pass before
an automatic rejoin is issued. This can be adjusted by tuning
the POLL_INTERVAL_MS variable inside the net service's
connection_manager.rs module.