emulation: bq27421: correct endianness
Because of the previous commit, endianness was incorrect and we weren't reading the full range of values. Correct the endianness and support continuous reads. Also expose various settings so they may be adjusted. Signed-off-by: Sean Cross <sean@xobs.io>
This commit is contained in:
parent
cd19fcba57
commit
df03f8c820
1 changed files with 14 additions and 13 deletions
|
|
@ -120,13 +120,14 @@ namespace Antmicro.Renode.Peripherals.Sensors
|
|||
{
|
||||
result[i] = RegistersCollection.Read(regAddress + i);
|
||||
}
|
||||
regAddress += count;
|
||||
return result;
|
||||
}
|
||||
public decimal Temperature { get; set; }
|
||||
private uint Voltage;
|
||||
private uint SoC;
|
||||
private uint AvgCur;
|
||||
private uint RemainingCapacity;
|
||||
public uint Voltage;
|
||||
public uint SoC;
|
||||
public int AvgCur;
|
||||
public uint RemainingCapacity;
|
||||
|
||||
public GPIO IRQ { get; }
|
||||
public ByteRegisterCollection RegistersCollection { get; }
|
||||
|
|
@ -134,25 +135,25 @@ namespace Antmicro.Renode.Peripherals.Sensors
|
|||
private void DefineRegisters()
|
||||
{
|
||||
Registers.TempLow.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "TEMPERATURE_SENSOR_LOW", valueProviderCallback: _ => ((uint)(Temperature * 10)) >> 8);
|
||||
Registers.TempHigh.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "TEMPERATURE_SENSOR_LOW", valueProviderCallback: _ => ((uint)(Temperature * 10)));
|
||||
Registers.TempHigh.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "TEMPERATURE_SENSOR_LOW", valueProviderCallback: _ => ((uint)(Temperature * 10)) >> 8);
|
||||
Registers.VoltLow.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "VOLTAGE_LOW", valueProviderCallback: _ => Voltage >> 8);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "VOLTAGE_LOW", valueProviderCallback: _ => Voltage);
|
||||
Registers.VoltHigh.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "VOLTAGE_HIGH", valueProviderCallback: _ => Voltage);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "VOLTAGE_HIGH", valueProviderCallback: _ => Voltage >> 8);
|
||||
Registers.AvgCurLow.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "AVGCUR_LOW", valueProviderCallback: _ => AvgCur >> 8);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "AVGCUR_LOW", valueProviderCallback: _ => (uint)AvgCur);
|
||||
Registers.AvgCurHigh.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "AVGCUR_HIGH", valueProviderCallback: _ => AvgCur);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "AVGCUR_HIGH", valueProviderCallback: _ => (uint)(AvgCur >> 8));
|
||||
Registers.RmLow.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "RM_LOW", valueProviderCallback: _ => RemainingCapacity >> 8);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "RM_LOW", valueProviderCallback: _ => RemainingCapacity);
|
||||
Registers.RmHigh.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "RM_HIGH", valueProviderCallback: _ => RemainingCapacity);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "RM_HIGH", valueProviderCallback: _ => RemainingCapacity >> 8);
|
||||
Registers.SocLow.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "SOC_LOW", valueProviderCallback: _ => SoC);
|
||||
Registers.SocHigh.Define(this)
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "SOC_HIGH", valueProviderCallback: _ => SoC);
|
||||
.WithValueField(0, 8, FieldMode.Read, name: "SOC_HIGH", valueProviderCallback: _ => SoC >> 8);
|
||||
}
|
||||
|
||||
private void RegistersAutoIncrement()
|
||||
|
|
|
|||
Loading…