xous-core/services/net/src/main.rs

1234 lines
67 KiB
Rust
Raw Normal View History

#![cfg_attr(target_os = "none", no_std)]
#![cfg_attr(target_os = "none", no_main)]
mod api;
use api::*;
use num_traits::*;
use com::api::{ComIntSources, Ipv4Conf, NET_MTU};
mod device;
mod connection_manager;
2021-10-28 10:50:07 +00:00
use xous::{Message, CID, SID, msg_scalar_unpack, msg_blocking_scalar_unpack};
use xous_ipc::Buffer;
use std::collections::BTreeMap;
use std::collections::HashMap;
use std::convert::TryInto;
use smoltcp::phy::{Medium, Device};
use smoltcp::iface::{InterfaceBuilder, NeighborCache, Routes, Interface};
use smoltcp::socket::{IcmpEndpoint, IcmpPacketMetadata, IcmpSocket, IcmpSocketBuffer, SocketSet};
use smoltcp::wire::{
EthernetAddress, IpAddress, IpCidr, Ipv4Address, Ipv4Cidr, IpEndpoint
};
use smoltcp::wire::{
Icmpv4Packet, Icmpv4Repr, Icmpv6Packet, Icmpv6Repr,
};
use byteorder::{ByteOrder, NetworkEndian};
use smoltcp::socket::{UdpPacketMetadata, UdpSocket, UdpSocketBuffer, SocketHandle, TcpSocket, TcpSocketBuffer};
use smoltcp::time::Instant;
use std::thread;
use std::sync::Arc;
use core::sync::atomic::{AtomicU32, Ordering};
const PING_DEFAULT_TIMEOUT_MS: u32 = 10_000;
fn set_ipv4_addr<DeviceT>(iface: &mut Interface<'_, DeviceT>, cidr: Ipv4Cidr)
where
DeviceT: for<'d> Device<'d>,
{
iface.update_ip_addrs(|addrs| {
let dest = addrs.iter_mut().next().expect("trouble updating ipv4 addresses in routing table");
*dest = IpCidr::Ipv4(cidr);
});
}
#[derive(num_derive::FromPrimitive, num_derive::ToPrimitive, Debug)]
enum WaitOp {
WaitMs,
PollAt,
Quit,
}
/// UdpState will return a full custom datastructure, and is designed to work with
/// a one-time use dedicated server created as part of the Net library code.
pub struct UdpState {
handle: SocketHandle,
cid: CID,
sid: SID,
}
/// PingConnection can return a Scalar: because of the simplicity of the return data
/// we give implementors the option to unpack the Scalar themselves within the main loop
/// of their event handler, *or* they can create a dedicated server that handles the return
/// code.
///
/// Unpacking the Scalar type is more efficient, but essentially requires a connection
/// to their private main loop server connection for the message to arrive, brokered via
/// xous-names. This can create a potential security concern, as the "unclaimed" connection
/// could be abused by a malicious process, which would have access to all of the dispatchable
/// opcodes of the main loop through that connection.
///
/// Thus, for security-sensitive processes, it is recommended that those create a single-purpose
/// server ID and broker the connection through that mechanism.
#[derive(Hash, PartialEq, Eq)]
pub struct PingConnection {
remote: IpAddress,
cid: CID,
retop: usize,
}
#[derive(Hash, PartialEq, Eq)]
pub struct TcpConnection {
remote: IpAddress,
remote_port: u16,
local_port: u16,
}
pub struct TcpState {
handle: SocketHandle,
cid: CID,
}
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
fn set_com_ints(com_int_list: &mut Vec::<ComIntSources>) {
com_int_list.clear();
com_int_list.push(ComIntSources::WlanIpConfigUpdate);
com_int_list.push(ComIntSources::WlanRxReady);
com_int_list.push(ComIntSources::BatteryCritical);
com_int_list.push(ComIntSources::Connect);
com_int_list.push(ComIntSources::Disconnect);
com_int_list.push(ComIntSources::WlanSsidScanUpdate);
com_int_list.push(ComIntSources::WlanSsidScanFinished);
com_int_list.push(ComIntSources::WfxErr);
}
#[xous::xous_main]
fn xmain() -> ! {
log_server::init_wait().unwrap();
log::set_max_level(log::LevelFilter::Info);
log::info!("my PID is {}", xous::process::id());
let xns = xous_names::XousNames::new().unwrap();
let net_sid = xns.register_name(api::SERVER_NAME_NET, None).expect("can't register server");
let net_conn = xous::connect(net_sid).unwrap();
log::trace!("registered with NS -- {:?}", net_sid);
// bring the EC into a sane state for the network -- that is, reset the EC
let mut llio = llio::Llio::new(&xns);
let com = com::Com::new(&xns).unwrap();
let timer = ticktimer_server::Ticktimer::new().unwrap();
// we need a trng for port numbers
let trng = trng::Trng::new(&xns).unwrap();
// hook the COM interrupt listener
let net_cid = xous::connect(net_sid).unwrap();
llio.hook_com_event_callback(Opcode::ComInterrupt.to_u32().unwrap(), net_cid).unwrap();
llio.com_event_enable(true).unwrap();
// setup the interrupt masks
let mut com_int_list: Vec::<ComIntSources> = vec![];
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
com.ints_get_active(&mut com_int_list).ok();
log::debug!("COM initial pending interrupts: {:?}", com_int_list);
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
set_com_ints(&mut com_int_list);
com.ints_enable(&com_int_list);
com_int_list.clear();
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
com.ints_get_active(&mut com_int_list).ok();
log::debug!("COM pending interrupts after enabling: {:?}", com_int_list);
const MAX_DELAY_THREADS: u32 = 10; // limit the number of concurrent delay threads. Typically we have 1-2 running at any time, but DoS conditions could lead to many more.
let delay_threads = Arc::new(AtomicU32::new(0));
let mut net_config: Option<Ipv4Conf> = None;
// storage for all our sockets
let mut sockets = SocketSet::new(vec![]);
// ping storage
// up to four concurrent pings in the queue
let icmp_rx_buffer = IcmpSocketBuffer::new(
vec![
IcmpPacketMetadata::EMPTY,
IcmpPacketMetadata::EMPTY,
IcmpPacketMetadata::EMPTY,
IcmpPacketMetadata::EMPTY
],
vec![0; 1024]);
let icmp_tx_buffer = IcmpSocketBuffer::new(
vec![
IcmpPacketMetadata::EMPTY,
IcmpPacketMetadata::EMPTY,
IcmpPacketMetadata::EMPTY,
IcmpPacketMetadata::EMPTY
],
vec![0; 1024]);
let mut icmp_socket = IcmpSocket::new(icmp_rx_buffer, icmp_tx_buffer);
let ident = 0x22b;
icmp_socket.bind(IcmpEndpoint::Ident(ident)).expect("couldn't bind to icmp socket");
let icmp_handle = sockets.add(icmp_socket);
let mut seq: u16 = 0;
// this record stores the origin time + IP address of the outgoing ping sequence number
let mut ping_destinations = HashMap::<PingConnection, HashMap::<u16, u64>>::new();
let mut ping_timeout_ms = PING_DEFAULT_TIMEOUT_MS;
// udp storage
let mut udp_handles = HashMap::<u16, UdpState>::new();
// UDP requires multiple copies. The way it works is that Tx can come from anyone;
// for Rx, copies of a CID,SID tuple are kept for every clone is kept in a HashMap. This
// allows for the Rx data to be cc:'d to each clone, and identified by SID upon drop
let mut udp_clones = HashMap::<u16, HashMap::<[u32; 4], CID>>::new(); // additional clones for UDP responders
// tcp storage
let mut tcp_handles = HashMap::<TcpConnection, TcpState>::new();
// other link storage
let neighbor_cache = NeighborCache::new(BTreeMap::new());
let ip_addrs = [IpCidr::new(Ipv4Address::UNSPECIFIED.into(), 0)];
let routes = Routes::new(BTreeMap::new());
let device = device::NetPhy::new(&xns);
// needed by ICMP to determine if we should compute checksums
let device_caps = device.capabilities();
let medium = device.capabilities().medium;
let mut builder = InterfaceBuilder::new(device)
.ip_addrs(ip_addrs)
.routes(routes);
if medium == Medium::Ethernet {
builder = builder
.ethernet_addr(EthernetAddress::from_bytes(&[0; 6]))
.neighbor_cache(neighbor_cache);
}
let mut iface = builder.finalize();
// DNS hooks - the DNS server can ask the Net crate to tickle it when IP configs change using these hooks
// Currently, we assume there is only one DNS server in Xous. I suppose you could
// upgrade the code to handle multiple DNS servers, but...why???
// ... nevermind, someone will invent a $reason because there was never a shiny
// new feature that a coder didn't love and *had* to have *right now*.
let mut dns_ipv4_hook = XousScalarEndpoint::new();
let mut dns_ipv6_hook = XousScalarEndpoint::new();
let mut dns_allclear_hook = XousScalarEndpoint::new();
log::trace!("ready to accept requests");
// register a suspend/resume listener
let sr_cid = xous::connect(net_sid).expect("couldn't create suspend callback connection");
let mut susres = susres::Susres::new(Some(susres::SuspendOrder::Early), &xns, api::Opcode::SuspendResume as u32, sr_cid).expect("couldn't create suspend/resume object");
// kick off the connection manager thread
let cm_sid = xous::create_server().expect("couldn't create connection manager server");
let cm_cid = xous::connect(cm_sid).unwrap();
let activity_interval = Arc::new(AtomicU32::new(0));
thread::spawn({
let activity_interval = activity_interval.clone();
move || {
connection_manager::connection_manager(cm_sid, activity_interval);
}
});
let mut cid_to_disconnect: Option<CID> = None;
loop {
let mut msg = xous::receive_message(net_sid).unwrap();
if let Some(dc_cid) = cid_to_disconnect.take() { // disconnect previous loop iter's connection after d/c OK response was sent
unsafe{
match xous::disconnect(dc_cid) {
Ok(_) => {},
Err(xous::Error::ServerNotFound) => {
log::trace!("Disconnect returned the expected error code for a remote that has been destroyed.")
},
Err(e) => {
log::error!("Attempt to de-allocate CID to destroyed server met with error: {:?}", e);
},
}
}
}
match FromPrimitive::from_usize(msg.body.id()) {
Some(Opcode::Ping) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let mut pkt = buf.to_original::<NetPingPacket, _>().unwrap();
let mut socket = sockets.get::<IcmpSocket>(icmp_handle);
if socket.can_send() {
log::trace!("sending ping to {:?}", pkt.endpoint);
let remote = IpAddress::from(pkt.endpoint);
// we take advantage of the fact that the same CID is always returned for repeated connect requests to the same SID.
let cid = match pkt.server {
XousServerId::PrivateSid(sid) => match xous::connect(SID::from_array(sid)) {
Ok(cid) => cid,
Err(e) => {
log::error!("Ping request with single-use callback SID is invalid. Aborting request. {:?}",e);
continue;
}
}
XousServerId::ServerName(name) => match xns.request_connection(name.to_str()) {
Ok(cid) => cid,
Err(e) => {
log::error!("Ping request received, but callback name '{}' is invalid. Aborting request. {:?}", name, e);
continue;
}
}
};
// this structure can be a HashMap key because it "should" be invariant across well-formed ping requests
let conn = PingConnection {
remote,
cid,
retop: pkt.return_opcode,
};
log::trace!("ping conn info: remote {:?} / cid: {} / retp: {}", remote, cid, pkt.return_opcode);
// this code will guarantee the sequence number goes up, but if multiple concurrent
// pings are in progress, they may not be directly in sequence. This is OK.
let now = timer.elapsed_ms();
if let Some(queue) = ping_destinations.get_mut(&conn) {
queue.insert(seq, now);
} else {
let mut new_queue = HashMap::<u16, u64>::new();
new_queue.insert(seq, now);
ping_destinations.insert(conn, new_queue);
};
// now emit the actual packet
let mut echo_payload = [0xffu8; 40];
NetworkEndian::write_i64(&mut echo_payload, now as i64);
match remote {
IpAddress::Ipv4(_) => {
let icmp_repr = Icmpv4Repr::EchoRequest {
ident,
seq_no: seq,
data: &echo_payload,
};
let icmp_payload = socket.send(icmp_repr.buffer_len(), remote).unwrap();
let mut icmp_packet = Icmpv4Packet::new_unchecked(icmp_payload);
icmp_repr.emit(&mut icmp_packet, &device_caps.checksum);
}
IpAddress::Ipv6(_) => {
// not sure if this is a valid thing to do, to just assign the source some number like this??
let src_ipv6 = IpAddress::v6(0xfdaa, 0, 0, 0, 0, 0, 0, 1);
let icmp_repr = Icmpv6Repr::EchoRequest {
ident,
seq_no: seq,
data: &echo_payload,
};
let icmp_payload = socket.send(icmp_repr.buffer_len(), remote).unwrap();
let mut icmp_packet = Icmpv6Packet::new_unchecked(icmp_payload);
icmp_repr.emit(
&src_ipv6,
&remote,
&mut icmp_packet,
&device_caps.checksum,
);
}
_ => unimplemented!(),
}
seq += 1;
// fire off a Pump to get the stack to actually transmit the ping; this call merely queues it for sending
xous::try_send_message(net_conn,
Message::new_scalar(
Opcode::NetPump.to_usize().unwrap(),
0, 0, 0, 0)
).ok();
pkt.sent_ok = Some(true);
} else {
pkt.sent_ok = Some(false);
}
buf.replace(pkt).expect("Xous couldn't issue response to Ping request");
}
Some(Opcode::PingSetTtl) => msg_scalar_unpack!(msg, ttl, _, _, _, {
let checked_ttl = if ttl > 255 {
255 as u8
} else {
ttl as u8
};
let mut socket = sockets.get::<IcmpSocket>(icmp_handle);
socket.set_hop_limit(Some(checked_ttl));
}),
Some(Opcode::PingGetTtl) => msg_blocking_scalar_unpack!(msg, _, _, _, _, {
let socket = sockets.get::<IcmpSocket>(icmp_handle);
let checked_ttl = if let Some(ttl) = socket.hop_limit() {
ttl
} else {
64 // because this is the default according to the smoltcp source code
};
xous::return_scalar(msg.sender, checked_ttl as usize).unwrap();
}),
Some(Opcode::PingSetTimeout) => msg_scalar_unpack!(msg, to, _, _, _, {
ping_timeout_ms = to as u32;
}),
Some(Opcode::PingGetTimeout) => msg_blocking_scalar_unpack!(msg, _, _, _, _, {
xous::return_scalar(msg.sender, ping_timeout_ms as usize).unwrap();
}),
Some(Opcode::DnsHookAddIpv4) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let hook = buf.to_original::<XousPrivateServerHook, _>().unwrap();
if dns_ipv4_hook.is_set() {
buf.replace(NetMemResponse::AlreadyUsed).unwrap();
} else {
dns_ipv4_hook.set(
xous::connect(SID::from_array(hook.one_time_sid)).unwrap(),
hook.op,
hook.args,
);
buf.replace(NetMemResponse::Ok).unwrap();
}
}
Some(Opcode::DnsHookAddIpv6) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let hook = buf.to_original::<XousPrivateServerHook, _>().unwrap();
if dns_ipv6_hook.is_set() {
buf.replace(NetMemResponse::AlreadyUsed).unwrap();
} else {
dns_ipv6_hook.set(
xous::connect(SID::from_array(hook.one_time_sid)).unwrap(),
hook.op,
hook.args,
);
buf.replace(NetMemResponse::Ok).unwrap();
}
}
Some(Opcode::DnsHookAllClear) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let hook = buf.to_original::<XousPrivateServerHook, _>().unwrap();
if dns_allclear_hook.is_set() {
buf.replace(NetMemResponse::AlreadyUsed).unwrap();
} else {
dns_allclear_hook.set(
xous::connect(SID::from_array(hook.one_time_sid)).unwrap(),
hook.op,
hook.args,
);
buf.replace(NetMemResponse::Ok).unwrap();
}
}
Some(Opcode::DnsUnhookAll) => msg_blocking_scalar_unpack!(msg, _, _, _, _, {
dns_ipv4_hook.clear();
dns_ipv6_hook.clear();
dns_allclear_hook.clear();
xous::return_scalar(msg.sender, 1).expect("couldn't ack unhook");
}),
Some(Opcode::TcpConnect) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
2022-01-29 08:09:59 +00:00
let mut tcpspec = buf.to_original::<NetTcpManage, _>().unwrap(); // need to define this
let address = IpAddress::from(tcpspec.ip_addr);
let remote_port = tcpspec.remote_port;
// initiates a new connection to a remote server consisting of an (Address:Port) tuple.
// multiple connections can exist to a server, and they are furhte differentiated by the return port
let tcp_rx_buffer = TcpSocketBuffer::new(vec![0; TCP_BUFFER_SIZE]);
let tcp_tx_buffer = TcpSocketBuffer::new(vec![0; TCP_BUFFER_SIZE]);
let mut tcp_socket = TcpSocket::new(tcp_rx_buffer, tcp_tx_buffer);
let local_port = (49152 + trng.get_u32().unwrap() % 16384) as u16;
match tcp_socket.connect((address, remote_port), local_port) {
Ok(_) => {
let connection = TcpConnection {
remote: address,
remote_port,
local_port,
};
let handle = sockets.add(tcp_socket);
let sid = tcpspec.cb_sid;
let cid = xous::connect(SID::from_array(sid)).unwrap();
let tcp_cb_state = TcpState {
handle,
cid,
};
tcp_handles.insert(connection, tcp_cb_state);
tcpspec.result = Some(NetMemResponse::Ok);
}
Err(e) => {
match e {
smoltcp::Error::Illegal => {
tcpspec.result = Some(NetMemResponse::SocketInUse);
}
smoltcp::Error::Unaddressable => {
tcpspec.result = Some(NetMemResponse::Invalid);
}
_ => {
tcpspec.result = Some(NetMemResponse::LibraryError);
}
}
}
}
buf.replace(tcpspec).unwrap();
},
Some(Opcode::TcpTx) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let mut tcp_tx = buf.to_original::<NetTcpTransmit, _>().unwrap();
let connection = TcpConnection {
remote: IpAddress::from(tcp_tx.remote_addr),
remote_port: tcp_tx.remote_port,
local_port: tcp_tx.local_port,
};
if let Some(tcp_state) = tcp_handles.get(&connection) {
let mut socket = sockets.get::<TcpSocket>(tcp_state.handle);
2022-01-29 08:09:59 +00:00
if socket.can_send() {
tcp_tx.result = match socket.send_slice(&tcp_tx.data) {
2022-01-29 08:09:59 +00:00
Ok(octets) => {
tcp_tx.len = octets as u16;
Some(NetMemResponse::Ok)
},
Err(_) => Some(NetMemResponse::LibraryError),
}
} else {
// inform the sender it should retry
tcp_tx.result = Some(NetMemResponse::SocketInUse);
}
} else {
tcp_tx.result = Some(NetMemResponse::Invalid);
}
buf.replace(tcp_tx).unwrap();
},
2022-01-29 08:09:59 +00:00
Some(Opcode::TcpClose) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let mut tcpspec = buf.to_original::<NetTcpManage, _>().unwrap(); // need to define this
let address = IpAddress::from(tcpspec.ip_addr);
let remote_port = tcpspec.remote_port;
if let Some(local_port) = tcpspec.local_port {
let connection = TcpConnection {
remote: IpAddress::from(tcpspec.ip_addr),
remote_port: tcpspec.remote_port,
local_port,
};
if let Some(tcp_state) = tcp_handles.remove(&connection) {
sockets.get::<TcpSocket>(tcp_state.handle).close();
tcpspec.result = Some(NetMemResponse::Ok);
} else {
tcpspec.result = Some(NetMemResponse::Invalid);
}
} else {
tcpspec.result = Some(NetMemResponse::Invalid);
}
buf.replace(tcpspec).unwrap();
}
Some(Opcode::UdpBind) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
2021-10-17 20:02:55 +00:00
let udpspec = buf.to_original::<NetUdpBind, _>().unwrap();
let buflen = if let Some(maxlen) = udpspec.max_payload {
maxlen as usize
} else {
NET_MTU as usize
};
2021-10-17 20:02:55 +00:00
if udp_handles.contains_key(&udpspec.port) {
// if we're already connected, just register the extra listener in the clones array
let sid = udpspec.cb_sid;
let cid = xous::connect(SID::from_array(sid)).unwrap();
if let Some(clone_map) = udp_clones.get_mut(&udpspec.port) {
// if a clone already exists, put the additional clone into the map
match clone_map.insert(sid, cid) {
Some(_) => {
log::error!("Something went wrong in a UDP clone operation -- same SID registered twice");
buf.replace(NetMemResponse::SocketInUse).unwrap()
}, // the same SID has double-registered, this is an error
None => buf.replace(NetMemResponse::Ok).unwrap()
}
} else {
// otherwise, create the clone mapping entry
let mut newmap = HashMap::new();
newmap.insert(sid, cid);
udp_clones.insert(
udpspec.port,
newmap
);
}
buf.replace(NetMemResponse::Ok).unwrap();
2021-10-17 20:02:55 +00:00
} else {
let udp_rx_buffer = UdpSocketBuffer::new(vec![UdpPacketMetadata::EMPTY], vec![0; buflen]);
let udp_tx_buffer = UdpSocketBuffer::new(vec![UdpPacketMetadata::EMPTY], vec![0; buflen]);
let mut udp_socket = UdpSocket::new(udp_rx_buffer, udp_tx_buffer);
match udp_socket.bind(udpspec.port) {
Ok(_) => {
let sid = SID::from_array(udpspec.cb_sid);
let udpstate = UdpState {
handle: sockets.add(udp_socket),
cid: xous::connect(sid).unwrap(),
sid
};
udp_handles.insert(udpspec.port, udpstate);
2021-10-17 20:02:55 +00:00
buf.replace(NetMemResponse::Ok).unwrap();
}
Err(e) => {
log::error!("Udp couldn't bind to socket: {:?}", e);
buf.replace(NetMemResponse::Invalid).unwrap();
}
}
}
},
Some(Opcode::UdpClose) => {
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let udpspec = buf.to_original::<NetUdpBind, _>().unwrap();
// need to find the SID that matches either in the clone array, or the primary binding.
// first check the clone array, then fall back to the primary binding
match udp_clones.get_mut(&udpspec.port) {
Some(clone_map) => {
match clone_map.remove(&udpspec.cb_sid) {
Some(cid) => {
cid_to_disconnect = Some(cid);
buf.replace(NetMemResponse::Ok).unwrap();
continue;
}
None => {}
}
}
None => {}
}
2021-10-17 20:02:55 +00:00
match udp_handles.remove(&udpspec.port) {
Some(udpstate) => {
if udpstate.sid == SID::from_array(udpspec.cb_sid) {
match udp_clones.get_mut(&udpspec.port) {
// if the clone map is nil, close the socket, we're done
None => {
sockets.get::<UdpSocket>(udpstate.handle).close();
buf.replace(NetMemResponse::Ok).unwrap();
}
// if the clone map has entries, promote an arbitrary map entry to the primary handle
Some(clone_map) => {
if clone_map.len() == 0 {
// removing SIDs doesn't remove the map, so it's possible to have an empty mapping. Get rid of it, and we're done.
udp_clones.remove(&udpspec.port);
sockets.get::<UdpSocket>(udpstate.handle).close();
buf.replace(NetMemResponse::Ok).unwrap();
} else {
// take an arbitrary key, re-insert it into the handles map.
let new_primary_sid = *clone_map.keys().next().unwrap(); // unwrap is appropriate because len already checked as not 0
let udpstate = UdpState {
handle: udpstate.handle,
cid: *clone_map.get(&new_primary_sid).unwrap(),
sid: SID::from_array(new_primary_sid),
};
udp_handles.insert(udpspec.port, udpstate);
// now remove it from the clone map
clone_map.remove(&new_primary_sid);
// clean up the clone map if it's empty
if clone_map.len() == 0 {
udp_clones.remove(&udpspec.port);
}
buf.replace(NetMemResponse::Ok).unwrap();
}
}
}
}
2021-10-17 20:02:55 +00:00
}
_ => {
buf.replace(NetMemResponse::Invalid).unwrap()
}
}
},
2021-10-18 17:41:22 +00:00
Some(Opcode::UdpTx) => {
use std::convert::TryInto;
let mut buf = unsafe{Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())};
let udp_tx = buf.to_original::<NetUdpTransmit, _>().unwrap();
match udp_handles.get_mut(&udp_tx.local_port) {
Some(udpstate) => {
if let Some(dest_socket) = udp_tx.dest_socket {
let endpoint = IpEndpoint::new(
dest_socket.addr.try_into().unwrap(),
dest_socket.port
);
let mut socket = sockets.get::<UdpSocket>(udpstate.handle);
match socket.send_slice(&udp_tx.data[..udp_tx.len as usize], endpoint) {
Ok(_) => buf.replace(NetMemResponse::Sent(udp_tx.len)).unwrap(),
_ => buf.replace(NetMemResponse::LibraryError).unwrap(),
}
// fire off a Pump to get the stack to actually transmit the ping; the send call merely queues it for sending
xous::try_send_message(net_conn,
Message::new_scalar(
Opcode::NetPump.to_usize().unwrap(),
0, 0, 0, 0)
).ok();
2021-10-18 17:41:22 +00:00
} else {
buf.replace(NetMemResponse::Invalid).unwrap()
}
}
_ => buf.replace(NetMemResponse::Invalid).unwrap()
}
},
Some(Opcode::UdpSetTtl) => msg_scalar_unpack!(msg, ttl, port, _, _, {
match udp_handles.get_mut(&(port as u16)) {
Some(udpstate) => {
let mut socket = sockets.get::<UdpSocket>(udpstate.handle);
let checked_ttl = if ttl > 255 || ttl == 0 {
64
} else {
ttl as u8
};
socket.set_hop_limit(Some(checked_ttl));
}
None => {
log::error!("Set TTL message received, but no port was bound! port {} ttl {}", port, ttl);
}
}
}),
Some(Opcode::UdpGetTtl) => msg_blocking_scalar_unpack!(msg, port, _, _, _, {
match udp_handles.get_mut(&(port as u16)) {
Some(udpstate) => {
let socket = sockets.get::<UdpSocket>(udpstate.handle);
let ttl = socket.hop_limit().unwrap_or(64); // 64 is the value used by smoltcp if hop limit isn't set
xous::return_scalar(msg.sender, ttl as usize).expect("couldn't return TTL");
}
None => {
log::error!("Set TTL message received, but no port was bound! port {}", port);
xous::return_scalar(msg.sender, usize::MAX).expect("couldn't return TTL");
}
}
}),
Some(Opcode::ComInterrupt) => {
com_int_list.clear();
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
match com.ints_get_active(&mut com_int_list) {
Ok((maybe_rxlen, ints, raw_rxlen)) => {
log::debug!("COM got interrupts: {:?}, {:?}", com_int_list, maybe_rxlen);
// forward the interrupt to the connection manager as well
match xous::try_send_message(cm_cid, Message::new_scalar(
connection_manager::ConnectionManagerOpcode::ComInt.to_usize().unwrap(),
ints,
raw_rxlen,
0, 0
)) {
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Our net queue runneth over, interrupts were dropped.");
},
Err(e) => {
log::error!("Unhandled error forwarding ComInt to the connection manager: {:?}", e);
}
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
};
for &pending in com_int_list.iter() {
if pending == ComIntSources::Invalid {
log::error!("COM interrupt vector had an error, ignoring event.");
continue;
}
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
}
for &pending in com_int_list.iter() {
match pending {
ComIntSources::BatteryCritical => {
log::warn!("Battery is critical! TODO: go into SHIP mode");
},
ComIntSources::WlanIpConfigUpdate => {
// right now the WLAN implementation only does IPV4. So IPV6 compatibility ends here.
// if IPV6 gets added to the EC/COM bus, ideally this is one of a couple spots in Xous that needs a tweak.
let config = com.wlan_get_config().expect("couldn't retrieve updated ipv4 config");
log::info!("Network config acquired: {:?}", config);
net_config = Some(config);
let mac = EthernetAddress::from_bytes(&config.mac);
// we need to clear the ARP cache in case we've migrated base stations (e.g. in a wireless network
// that is coverd by multiple AP), as the host AP's MAC address would have changed, and we wouldn't
// be able to route responses back. I can't seem to find a function in smoltcp 0.7.5 that allows us
// to neatly clear the ARP cache as the BTreeMap that underlies it is moved into the container and
// no "clear" API is exposed, so let's just rebuild the whole interface if we get a DHCP renewal.
let neighbor_cache = NeighborCache::new(BTreeMap::new());
let ip_addrs = [IpCidr::new(Ipv4Address::UNSPECIFIED.into(), 0)];
let routes = Routes::new(BTreeMap::new());
let device = device::NetPhy::new(&xns);
let medium = device.capabilities().medium;
let mut builder = InterfaceBuilder::new(device)
.ip_addrs(ip_addrs)
.routes(routes);
if medium == Medium::Ethernet {
builder = builder
.ethernet_addr(mac)
.neighbor_cache(neighbor_cache);
}
iface = builder.finalize();
let ip_addr =
Ipv4Cidr::new(Ipv4Address::new(
config.addr[0],
config.addr[1],
config.addr[2],
config.addr[3],
), 24);
set_ipv4_addr(&mut iface, ip_addr);
let default_v4_gw = Ipv4Address::new(
config.gtwy[0],
config.gtwy[1],
config.gtwy[2],
config.gtwy[3],
);
// reset the default route, in case it has changed
iface.routes_mut().remove_default_ipv4_route();
match iface.routes_mut().add_default_ipv4_route(default_v4_gw) {
Ok(route) => log::info!("routing table updated successfully [{:?}]", route),
Err(e) => log::error!("routing table update error: {}", e),
}
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
dns_allclear_hook.notify();
dns_ipv4_hook.notify_custom_args([
Some(u32::from_be_bytes(config.dns1)),
None, None, None,
]);
// the current implementation always returns 0.0.0.0 as the second dns,
// ignore this if that's what we've got; otherwise, pass it on.
if config.dns2 != [0, 0, 0, 0] {
dns_ipv4_hook.notify_custom_args([
Some(u32::from_be_bytes(config.dns2)),
None, None, None,
]);
}
},
ComIntSources::WlanRxReady => {
activity_interval.store(0, Ordering::Relaxed); // reset the activity interval to 0
if let Some(_config) = net_config {
if let Some(rxlen) = maybe_rxlen {
match iface.device_mut().push_rx_avail(rxlen) {
None => {} //log::info!("pushed {} bytes avail to iface", rxlen),
Some(_) => log::warn!("Got more packets, but smoltcp didn't drain them in time"),
}
match xous::try_send_message(
net_conn,
Message::new_scalar(Opcode::NetPump.to_usize().unwrap(), 0, 0, 0, 0)
) {
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Our net queue runneth over, packets will be dropped.");
},
Err(e) => {
log::error!("Unhandled error sending NetPump to self: {:?}", e);
}
}
} else {
log::error!("Got RxReady interrupt but no packet length specified!");
}
}
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
},
_ => {
log::debug!("Unhandled: {:?}", pending);
}
}
}
THE BALDEST YAK: keyboard injection now working I wrote in a commit yesterday how there was no ROI on doing this yet somehow I kept on doing it. I blame poor impulse control. Turns out there was a series of race conditions and bugs that caused this thing to "mostly work" on the first go at it but really hard to debug and get very right. 1. Litex UART has a weird undocumented API. You advance the Rx FIFO by writing `1` to the PENDING bit, and no other way. However, you determine if there are any more characters to receive by reading the EMPTY bit and seeing if it is 1. The previous method wrote `1` to the PENDING bit and then used the PENDING bit to see if a character was available, under the theory that the PENDING bit would be set again if there was still a character. This is somewhat true, except that the PENDING bit is set only some amount of time later which is about comparable to a few CPU instructions, so if you had a fast loop path the PENDING bit would show as cleared and you'd exit, which would cause no further interrupts to fire because the interrupt was effecitvely not acknowledged. This isn't written up anywhere but I figured this out by just reading the source code for Litex UART and BIOS: https://github.com/enjoy-digital/litex/blob/e8be3915041707860e70b15d062661fc1f67a09f/litex/soc/cores/uart.py#L264-L279 https://github.com/enjoy-digital/litex/blob/ccd3ab17be1f8770c59ec1c62e0285d3bac3cc26/litex/soc/software/libbase/uart.c#L38-L44 2. I had the Key Injector IP block in the `sys` domain, which would have its clock cut when the CPU went to sleep, which would cause input characters to disappear when the CPU went into power saving. moving this to "always on" domain fixes that. 3. I had the UART PHY in the always on block (so you could send or receive exactly one character), but not the separate UART block (which contained the FIFOs). The UART block would also go into power savings, and this would cause FIFO entries to go missing. 4. Escape sequences get sent as a burst of characters. The Key Injector originally did not have a FIFO of its own, so it would only remember the *last* key of the sequence that was written, causing some keys to be dropped occassionally. Adding a 16-deep FIFO to the injector fixes this. 5. The code I had to read out the injector's results was designed with the "strobe" bit (to indicate that the FIFO had characters) in the same regsiter as the character itself. Thus the loop that 1. checked if the fifo was empty then 2. read and forwarded the character would actually perform two reads from the FIFO. However, this "mostly worked" I think because the FIFO retains the last value that was written even when it was empty, so if only one character was read at a time everything was fine. It only didn't work when you stuffed two characters in there, as you'd drop the first one. Reading the FIFO once and then interpreting the code with a bitmask fixes this. 6. The escape sequences, in their full glory with no dropped characters, required a refactored parsing routine, which I have now added. 7. backspace->delete mappings, the bane of computer engineers since 1960. OK. very bald yak. Here I lay down the shears next to several mooshi pillows stuffed with the finest Yak hair.
2022-01-28 07:17:47 +00:00
com.ints_ack(&com_int_list);
},
Err(xous::Error::Timeout) => {
log::warn!("Interrupt fetch from COM timed out.");
// bread crumb: this is a "normal" error to throw when the EC is being reset,
// or when it is handling the reset of the wifi subsystem, so it's not fatal.
// However, if we see this repeatedly, it might be a good idea to add some sort
// of event counter to log the number of times we've seen this consecutively and
// if it's too much, issue a reset to the EC.
// refresh the interrupt list to the EC, just in case it lost the prior list
timer.sleep_ms(1000).unwrap(); // a brief delay because if the EC wasn't responding before, it probably needs /some/ time before being able to handle this next message
set_com_ints(&mut com_int_list);
com.ints_enable(&com_int_list);
com_int_list.clear();
}
_ => {
// not fatal, just report it.
log::error!("Unhanlded error in COM interrupt fetch");
}
}
}
Some(Opcode::NetPump) => {
let timestamp = Instant::from_millis(timer.elapsed_ms() as i64);
match iface.poll(&mut sockets, timestamp) {
Ok(_) => { }
Err(e) => {
log::debug!("poll error: {}", e);
}
}
2021-10-17 20:02:55 +00:00
// this block handles TCP rx
{
for (connection, tcp_state) in tcp_handles.iter() {
let mut socket = sockets.get::<TcpSocket>(tcp_state.handle);
if socket.can_recv() {
match socket
.recv(|data| {
let mut response = NetTcpResponse {
remote_ip_addr: NetIpAddr::from(connection.remote),
remote_port: connection.remote_port,
len: data.len() as u16,
data: [0; TCP_BUFFER_SIZE],
};
for(&src, dst) in data.iter().zip(response.data.iter_mut()) {
*dst = src;
}
let buf = Buffer::into_buf(response).expect("couldn't convert TCP response to memory message");
buf.send(tcp_state.cid, NetTcpCallback::RxData.to_u32().unwrap()).expect("couldn't send TCP response");
(data.len(), ())
}) {
Ok(_) => (),
Err(e) => match e {
smoltcp::Error::Illegal => {
log::warn!("TCP fast open not supported");
},
smoltcp::Error::Finished => {
log::warn!("TCP packet received after close");
},
_ => {
log::warn!("Unknown TCP error");
}
}
}
}
}
}
// this block handles UDP
2021-10-17 20:02:55 +00:00
{
for (port, udpstate) in udp_handles.iter() {
let handle = udpstate.handle;
2021-10-17 20:02:55 +00:00
let mut socket = sockets.get::<UdpSocket>(handle);
match socket.recv() {
Ok((data, endpoint)) => {
log::trace!(
"udp:{} recv data: {:x?} from {}",
2021-10-17 20:02:55 +00:00
port,
data,
2021-10-17 20:02:55 +00:00
endpoint
);
// return the data/endpoint tuple to the caller
let mut response = NetUdpResponse {
endpoint_ip_addr: NetIpAddr::from(endpoint.addr),
len: data.len() as u16,
endpoint_port: endpoint.port,
data: [0; UDP_RESPONSE_MAX_LEN],
};
for (&src, dst) in data.iter().zip(response.data.iter_mut()) {
*dst = src;
}
let buf = Buffer::into_buf(response).expect("couldn't convert UDP response to memory message");
buf.send(udpstate.cid, NetUdpCallback::RxData.to_u32().unwrap()).expect("couldn't send UDP response");
// now send copies to the cloned receiver array, if they exist
if let Some(clone_map) = udp_clones.get(port) {
for &cids in clone_map.values() {
let buf = Buffer::into_buf(response).expect("couldn't convert UDP response to memory message");
buf.send(cids, NetUdpCallback::RxData.to_u32().unwrap()).expect("couldn't send UDP response");
}
}
2021-10-17 20:02:55 +00:00
}
Err(_) => {
// do nothing
},
};
}
}
// this block contains the ICMP Rx handler. Tx is initiated by an incoming message to the Net crate.
{
let mut socket = sockets.get::<IcmpSocket>(icmp_handle);
if !socket.is_open() {
log::error!("ICMP socket isn't open, something went wrong...");
}
if socket.can_recv() {
let (payload, _) = socket.recv().expect("couldn't receive on socket despite asserting availability");
log::trace!("icmp payload: {:x?}", payload);
let now = timer.elapsed_ms();
for (connection, waiting_queue) in ping_destinations.iter_mut() {
let remote_addr = connection.remote;
match remote_addr {
IpAddress::Ipv4(_) => {
let icmp_packet = Icmpv4Packet::new_checked(&payload).unwrap();
let icmp_repr =
Icmpv4Repr::parse(&icmp_packet, &device_caps.checksum).unwrap();
if let Icmpv4Repr::EchoReply { seq_no, data, .. } = icmp_repr {
log::trace!("got icmp seq no {} / data: {:x?}", seq_no, data);
if let Some(_) = waiting_queue.get(&seq_no) {
let packet_timestamp_ms = NetworkEndian::read_i64(data);
waiting_queue.remove(&seq_no);
// use try_send_message because we don't want to block if the recipient's queue is full;
// instead, the message is just dropped
match xous::try_send_message(connection.cid,
Message::new_scalar(
connection.retop,
NetPingCallback::NoErr.to_usize().unwrap(),
u32::from_be_bytes(remote_addr.as_bytes().try_into().unwrap()) as usize,
seq_no as usize,
(now as i64 - packet_timestamp_ms) as usize,
)
) {
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Got seq {} response, but upstream server queue is full; dropping.", &seq_no);
},
Err(e) => {
log::error!("Unhandled error: {:?}; ignoring", e);
}
}
}
} else if let Icmpv4Repr::DstUnreachable { reason, header, .. } = icmp_repr {
log::warn!("Got dst unreachable {:?}: {:?}", header.dst_addr, reason);
let reason_code: u8 = From::from(reason);
match xous::try_send_message(connection.cid,
Message::new_scalar(
connection.retop,
NetPingCallback::Unreachable.to_usize().unwrap() | (reason_code as usize) << 24,
u32::from_be_bytes(remote_addr.as_bytes().try_into().unwrap()) as usize,
0,
0,
)
) {
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Got dst {:?} unreachable, but upstream server queue is full; dropping.", remote_addr);
},
Err(e) => {
log::error!("Unhandled error: {:?}; ignoring", e);
}
}
} else {
log::error!("got unhandled ICMP type, ignoring!");
}
}
IpAddress::Ipv6(_) => {
// NOTE: actually not sure what src_ipv6 should be. This is just from an example.
let src_ipv6 = IpAddress::v6(0xfdaa, 0, 0, 0, 0, 0, 0, 1);
let icmp_packet = Icmpv6Packet::new_checked(&payload).unwrap();
let icmp_repr = Icmpv6Repr::parse(
&remote_addr,
&src_ipv6,
&icmp_packet,
&device_caps.checksum,
)
.unwrap();
let ra = remote_addr.as_bytes();
if let Icmpv6Repr::EchoReply { seq_no, data, .. } = icmp_repr {
if let Some(_) = waiting_queue.get(&seq_no) {
let packet_timestamp_ms = NetworkEndian::read_i64(data);
waiting_queue.remove(&seq_no);
match xous::try_send_message(connection.cid,
Message::new_scalar(
connection.retop,
NetPingCallback::NoErr.to_usize().unwrap(),
u32::from_be_bytes(ra[..4].try_into().unwrap()) as usize,
u32::from_be_bytes(ra[12..].try_into().unwrap()) as usize,
(now as i64 - packet_timestamp_ms) as usize,
)
) {
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Got seq {} response, but upstream server queue is full; dropping.", &seq_no);
},
Err(e) => {
log::error!("Unhandled error: {:?}; ignoring", e);
}
}
}
} else if let Icmpv6Repr::DstUnreachable { reason, header, .. } = icmp_repr {
let reason_code: u8 = From::from(reason);
log::warn!("Got dst unreachable {:?}: {:?}", header.dst_addr, reason);
match xous::try_send_message(connection.cid,
Message::new_scalar(
connection.retop,
NetPingCallback::Unreachable.to_usize().unwrap() | (reason_code as usize) << 24,
u32::from_be_bytes(ra[..4].try_into().unwrap()) as usize,
u32::from_be_bytes(ra[8..12].try_into().unwrap()) as usize,
u32::from_be_bytes(ra[12..].try_into().unwrap()) as usize,
)
){
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Got dst {:?} unreachable, but upstream server queue is full; dropping.", remote_addr);
},
Err(e) => {
log::error!("Unhandled error: {:?}; ignoring", e);
}
}
} else {
log::error!("got unhandled ICMP type, ignoring!");
}
}
_ => unimplemented!(),
}
}
}
}
// this block handles ICMP retirement; it runs everytime we pump the block
{
let now = timer.elapsed_ms();
// notify the callback to drop its connection, because the queue is now empty
// do this before we clear the queue, because we want the Drop message to come on the iteration
// *after* the queue is empty.
ping_destinations.retain(|conn, v|
if v.len() == 0 {
log::debug!("Dropping ping record for {:?}", conn.remote);
let ra = conn.remote.as_bytes();
match xous::send_message(conn.cid,
Message::new_scalar( // we should wait if the queue is full, as the "Drop" message is important
conn.retop,
NetPingCallback::Drop.to_usize().unwrap(),
u32::from_be_bytes(ra[..4].try_into().unwrap()) as usize,
if ra.len() == 16 {u32::from_be_bytes(ra[12..16].try_into().unwrap()) as usize} else {0},
0,
)
) {
Ok(_) => {},
Err(xous::Error::ServerNotFound) => {
log::debug!("Server already dropped before we could send it a drop message. Ignoring.");
}
Err(e) => {
panic!("couldn't send Drop on empty queue from Ping server: {:?}", e);
}
}
match unsafe{xous::disconnect(conn.cid)} {
Ok(_) => {},
Err(xous::Error::ServerNotFound) => {
log::debug!("Disconnected from a server that has already disappeared. Moving on.");
}
Err(e) => {
panic!("Unhandled error disconnecting from ping server: {:?}", e);
}
}
false
} else {
true
}
);
// now: sequence through the waiting_queue and remove entries that have hit our timeout
for (conn, waiting_queue) in ping_destinations.iter_mut() {
let ra = conn.remote.as_bytes();
waiting_queue.retain(|&seq, &mut start_time|
if now - start_time > ping_timeout_ms as u64 {
log::debug!("timeout - removing {:?}, {}", conn.remote, seq);
match xous::try_send_message(conn.cid,
Message::new_scalar( // we should wait if the queue is full, as the "Drop" message is important
conn.retop,
NetPingCallback::Timeout.to_usize().unwrap(),
u32::from_be_bytes(ra[..4].try_into().unwrap()) as usize,
seq as usize,
(now - start_time) as usize,
)
) {
Ok(_) => {},
Err(xous::Error::ServerQueueFull) => {
log::warn!("Got dst {:?} timeout, but upstream server queue is full; dropping.", conn.remote);
},
Err(xous::Error::ServerNotFound) => {
log::debug!("Callback server disappeared before we could inform it of timeout on {:?}, seq {}", conn.remote, seq);
},
Err(e) => {
log::error!("Unhandled error: {:?}; ignoring", e);
}
}
false
} else {
true
}
);
}
}
// establish our next check-up interval
let timestamp = Instant::from_millis(timer.elapsed_ms() as i64);
if let Some(delay) = iface.poll_delay(&sockets, timestamp) {
let delay_ms = delay.total_millis();
if delay_ms < 2 {
xous::try_send_message(net_conn,
Message::new_scalar(
Opcode::NetPump.to_usize().unwrap(),
0, 0, 0, 0)
).ok();
} else {
if delay_threads.load(Ordering::SeqCst) < MAX_DELAY_THREADS {
let prev_count = delay_threads.fetch_add(1, Ordering::SeqCst);
log::trace!("spawning checkup thread for {}ms. New total threads: {}", delay_ms, prev_count + 1);
thread::spawn({
let parent_conn = net_conn.clone();
let delay_threads = delay_threads.clone();
move || {
let tt = ticktimer_server::Ticktimer::new().unwrap();
tt.sleep_ms(delay_ms as usize).unwrap();
xous::try_send_message(parent_conn,
Message::new_scalar(
Opcode::NetPump.to_usize().unwrap(),
0, 0, 0, 0)
).ok();
let prev_count = delay_threads.fetch_sub(1, Ordering::SeqCst);
log::trace!("terminating checkup thread. New total threads: {}", prev_count - 1);
}
});
} else {
log::warn!("Could not queue delay of {}ms in net stack due to thread exhaustion.", delay_ms);
}
}
}
}
Some(Opcode::GetIpv4Config) => {
let mut buffer = unsafe {
Buffer::from_memory_message_mut(msg.body.memory_message_mut().unwrap())
};
let ser = if let Some(config) = net_config {
Some(config.encode_u16())
} else {
None
};
buffer.replace(ser).expect("couldn't return config");
},
Some(Opcode::SubscribeWifiStats) => {
let buffer = unsafe {
Buffer::from_memory_message(msg.body.memory_message().unwrap())
};
// have to transform it through the local memory space because you can't re-lend pages
let sub = buffer.to_original::<WifiStateSubscription, _>().unwrap();
let buf = Buffer::into_buf(sub).expect("couldn't convert to memory message");
buf.send(cm_cid, connection_manager::ConnectionManagerOpcode::SubscribeWifiStats.to_u32().unwrap()).expect("couldn't forward subscription request");
},
Some(Opcode::UnsubWifiStats) => msg_blocking_scalar_unpack!(msg, s0, s1, s2, s3, {
// now do something with the unsubscription
let response = xous::send_message(cm_cid, Message::new_blocking_scalar(
connection_manager::ConnectionManagerOpcode::UnsubWifiStats.to_usize().unwrap(),
s0, s1, s2, s3
)).expect("couldn't send unsub message");
if let xous::Result::Scalar1(val) = response {
xous::return_scalar(msg.sender, val).unwrap();
} else {
xous::return_scalar(msg.sender, 0).unwrap();
}
}),
Some(Opcode::Reset) => {
net_config = None;
let neighbor_cache = NeighborCache::new(BTreeMap::new());
let ip_addrs = [IpCidr::new(Ipv4Address::UNSPECIFIED.into(), 0)];
let routes = Routes::new(BTreeMap::new());
let device = device::NetPhy::new(&xns);
let medium = device.capabilities().medium;
let mut builder = InterfaceBuilder::new(device)
.ip_addrs(ip_addrs)
.routes(routes);
if medium == Medium::Ethernet {
builder = builder
.ethernet_addr(EthernetAddress::from_bytes(&[0; 6]))
.neighbor_cache(neighbor_cache);
}
iface = builder.finalize();
iface.routes_mut().remove_default_ipv4_route();
dns_allclear_hook.notify();
// question: do we need to clear the UDP and ICMP states?
xous::return_scalar(msg.sender, 1).unwrap();
}
Some(Opcode::SuspendResume) => xous::msg_scalar_unpack!(msg, token, _, _, _, {
com_int_list.clear();
com.ints_enable(&com_int_list); // disable all the interrupts
susres.suspend_until_resume(token).expect("couldn't execute suspend/resume");
// re-enable the interrupts
com_int_list.clear();
com_int_list.push(ComIntSources::WlanIpConfigUpdate);
com_int_list.push(ComIntSources::WlanRxReady);
com_int_list.push(ComIntSources::BatteryCritical);
com_int_list.push(ComIntSources::Connect);
com_int_list.push(ComIntSources::Disconnect);
com_int_list.push(ComIntSources::WlanSsidScanUpdate);
com_int_list.push(ComIntSources::WlanSsidScanFinished);
com_int_list.push(ComIntSources::WfxErr);
com.ints_enable(&com_int_list);
}),
2021-10-18 21:02:00 +00:00
Some(Opcode::Quit) => {
log::warn!("quit received");
break;
}
None => {
2021-10-18 21:06:05 +00:00
log::error!("couldn't convert opcode: {:?}", msg);
}
}
}
// clean up our program
log::trace!("main loop exit, destroying servers");
xous::send_message(cm_cid, Message::new_blocking_scalar(connection_manager::ConnectionManagerOpcode::Quit.to_usize().unwrap(), 0, 0, 0, 0)).expect("couldn't quit connection manager server");
unsafe{xous::disconnect(cm_cid).ok()};
xns.unregister_server(net_sid).unwrap();
xous::destroy_server(net_sid).unwrap();
log::trace!("quitting");
xous::terminate_process(0)
}