/*! \page page_calibration Calibration Application Notes
|
|
|
|
\tableofcontents
|
|
|
|
\section calibration_self Self-Calibration
|
|
|
|
UHD software comes with several self-calibration utilities for
|
|
minimizing IQ imbalance and DC offset. These utilities perform
|
|
calibration sweeps using transmit leakage into the receive path (special
|
|
equipment is not required). The results from a calibration are written
|
|
to a CSV file in the user's home directory. UHD software will
|
|
automatically apply corrections at runtime when the user re-tunes the
|
|
daughterboard LO. Calibration results are specific to an individual RF
|
|
board.
|
|
|
|
<b>Note:</b> When a calibration table is present, and the user wishes to
|
|
override the calibration settings through the API: the user should
|
|
re-apply the desired setting every time the LO is re-tuned.
|
|
|
|
UHD software comes with the following calibration utilities:
|
|
|
|
- **uhd_cal_rx_iq_balance:** - mimimizes RX IQ imbalance vs. LO
|
|
frequency
|
|
- **uhd_cal_tx_dc_offset:** - mimimizes TX DC offset vs. LO
|
|
frequency
|
|
- **uhd_cal_tx_iq_balance:** - mimimizes TX IQ imbalance vs. LO
|
|
frequency
|
|
|
|
The following RF frontends are supported by the self-calibration
|
|
utilities:
|
|
|
|
- RFX Series transceiver boards
|
|
- WBX Series transceiver boards
|
|
- SBX Series transceiver boards
|
|
- CBX Series transceiver boards
|
|
|
|
\subsection calibration_self_utils Calibration Utilities
|
|
|
|
UHD software installs the calibration utilities into
|
|
`<install-path>/bin`. **Disconnect** any external hardware from the
|
|
RF antenna ports, and run the following from the command line. Each
|
|
utility will take several minutes to complete. :
|
|
|
|
uhd_cal_rx_iq_balance --verbose --args=<optional device args>
|
|
uhd_cal_tx_iq_balance --verbose --args=<optional device args>
|
|
uhd_cal_tx_dc_offset --verbose --args=<optional device args>
|
|
|
|
See the output given by --help for more advanced options, such as:
|
|
manually choosing the frequency range and step size for the sweeps.
|
|
|
|
<b>Note:</b> Your daughterboard needs a serial number to run a calibration
|
|
utility. Some older daughterboards may not have a serial number. If this
|
|
is the case, run the following command to burn a serial number into the
|
|
daughterboard's EEPROM: :
|
|
|
|
<install dir>/lib/uhd/utils/usrp_burn_db_eeprom --ser=<desired serial> --args=<optional device args>
|
|
|
|
\subsection calibration_ Calibration Data
|
|
|
|
Calibration files are stored in the user's home/application directory.
|
|
They can easily be moved from machine to another by copying the "cal"
|
|
directory. Re-running a calibration utility will replace the existing
|
|
calibration file. The old calibration file will be renamed so it may be
|
|
recovered by the user.
|
|
|
|
- **Linux:** `${HOME}/.uhd/cal/`
|
|
- **Windows:** `%APPDATA%\.uhd\cal\`
|
|
|
|
*/
|
|