mirror of
https://github.com/saymrwulf/onnxruntime.git
synced 2026-05-15 20:50:42 +00:00
* Migrate winml to Microsoft Namespace (packaging changes are pending) * add ns_prefix toggle * fix packaging * Users/sheilk/add missing raw header (#3484) * add dualapipartition * wrong variable for repo root Co-authored-by: Sheil Kumar <sheilk@microsoft.com> * remove existence check to force failures * extra paren * dualapipartition needs to be referenced from the source * add microsoft.ai.machinelearning.dll to the output dir * rename the idl file so that assembly info is correctly added into the winmd * fix namespaces * update namespaces * default to microsoft, and add namespace override as build argument * update cmakesetings.json as well * remove from cmakelists.txt Co-authored-by: Sheil Kumar <sheilk@microsoft.com> Co-authored-by: Changming Sun <chasun@microsoft.com>
109 lines
No EOL
3.9 KiB
C++
109 lines
No EOL
3.9 KiB
C++
// Copyright (c) Microsoft Corporation. All rights reserved.
|
|
// Licensed under the MIT License.
|
|
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// WinMLTelemetryHelper
|
|
//
|
|
////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
|
|
|
|
#include "pch.h"
|
|
|
|
WinMLTelemetryHelper::WinMLTelemetryHelper()
|
|
: provider_(winml_trace_logging_provider) {
|
|
}
|
|
|
|
WinMLTelemetryHelper::~WinMLTelemetryHelper() {
|
|
}
|
|
|
|
void WinMLTelemetryHelper::LogWinMLShutDown() {
|
|
std::string message = BINARY_NAME;
|
|
message += " is unloaded";
|
|
WinMLTraceLoggingWrite(
|
|
provider_,
|
|
"WinMLShutDown",
|
|
TraceLoggingKeyword(WINML_PROVIDER_KEYWORD_DEFAULT),
|
|
TelemetryPrivacyDataTag(PDT_ProductAndServicePerformance),
|
|
TraceLoggingString(message.c_str(), "message"),
|
|
TraceLoggingKeyword(MICROSOFT_KEYWORD_MEASURES));
|
|
}
|
|
|
|
void WinMLTelemetryHelper::LogRuntimeError(HRESULT hr, PCSTR message, PCSTR file, PCSTR function, int line) {
|
|
if (!telemetry_enabled_)
|
|
return;
|
|
|
|
WinMLTraceLoggingWrite(
|
|
provider_,
|
|
"RuntimeError",
|
|
TraceLoggingKeyword(WINML_PROVIDER_KEYWORD_DEFAULT),
|
|
TelemetryPrivacyDataTag(PDT_ProductAndServicePerformance),
|
|
// Telemetry info
|
|
TraceLoggingUInt8(WINML_TLM_RUNTIME_ERROR_VERSION, "schemaVersion"),
|
|
// Error Info
|
|
TraceLoggingHResult(hr, "hResult"),
|
|
TraceLoggingString(message, "errormessage"),
|
|
TraceLoggingString(file, "file"),
|
|
TraceLoggingString(function, "function"),
|
|
TraceLoggingInt32(line, "line"),
|
|
TraceLoggingInt32(runtime_session_id_, "runtimeSessionId"),
|
|
TraceLoggingKeyword(MICROSOFT_KEYWORD_MEASURES));
|
|
}
|
|
|
|
void WinMLTelemetryHelper::LogRuntimeError(HRESULT hr, std::string message, PCSTR file, PCSTR function, int line) {
|
|
LogRuntimeError(hr, message.c_str(), file, function, line);
|
|
}
|
|
|
|
bool WinMLTelemetryHelper::IsMeasureSampled() {
|
|
// If the machine isn't sampled at Measure Level, return false.
|
|
return TraceLoggingProviderEnabled(provider_, WINEVENT_LEVEL_LOG_ALWAYS, MICROSOFT_KEYWORD_MEASURES);
|
|
}
|
|
|
|
void WinMLTelemetryHelper::LogRegisterOperatorKernel(
|
|
const char* name,
|
|
const char* domain,
|
|
int execution_type) {
|
|
if (!telemetry_enabled_)
|
|
return;
|
|
|
|
WinMLTraceLoggingWrite(
|
|
provider_,
|
|
"RegisterOperatorKernel",
|
|
TraceLoggingKeyword(WINML_PROVIDER_KEYWORD_DEFAULT),
|
|
TelemetryPrivacyDataTag(PDT_ProductAndServiceUsage),
|
|
// Telemetry info
|
|
TraceLoggingUInt8(WINML_TLM_RUNTIME_ERROR_VERSION, "schemaVersion"),
|
|
//op kernel info
|
|
TraceLoggingString(name, "name"),
|
|
TraceLoggingString(domain, "domain"),
|
|
TraceLoggingInt32(execution_type, "executionType"),
|
|
TraceLoggingInt32(runtime_session_id_, "runtimeSessionId"),
|
|
TraceLoggingKeyword(MICROSOFT_KEYWORD_MEASURES));
|
|
}
|
|
|
|
void WinMLTelemetryHelper::RegisterOperatorSetSchema(
|
|
const char* name,
|
|
uint32_t input_count,
|
|
uint32_t output_count,
|
|
uint32_t type_constraint_count,
|
|
uint32_t attribute_count,
|
|
uint32_t default_attribute_count) {
|
|
if (!telemetry_enabled_)
|
|
return;
|
|
|
|
WinMLTraceLoggingWrite(
|
|
provider_,
|
|
"RegisterOperatorSetSchema",
|
|
TraceLoggingKeyword(WINML_PROVIDER_KEYWORD_DEFAULT),
|
|
TelemetryPrivacyDataTag(PDT_ProductAndServiceUsage),
|
|
// Telemetry info
|
|
TraceLoggingUInt8(WINML_TLM_RUNTIME_ERROR_VERSION, "schemaVersion"),
|
|
//op kernel info
|
|
TraceLoggingString(name, "name"),
|
|
TraceLoggingInt32(input_count, "inputCount"), //stats
|
|
TraceLoggingInt32(output_count, "outputCount"),
|
|
TraceLoggingInt32(type_constraint_count, "typeConstraintCount"),
|
|
TraceLoggingInt32(attribute_count, "attributeCount"),
|
|
TraceLoggingInt32(default_attribute_count, "defaultAttributeCount"),
|
|
TraceLoggingInt32(runtime_session_id_, "runtime_session_id_"),
|
|